n42
Frequency Reference Bias
Setting
–99% to 99%
range
(Max. frequency = 100%)
D Analog Frequency Reference Filter Time (n43)
• The digital filter with a first-order lag can be set for analog frequency references to be input.
• This setting is ideal if the analog input signal changes rapidly or the signal is subject to noise interfer-
ence.
• The larger the set value is, the slower the response speed will be.
n43
Analog Frequency Reference Filter Time
Setting
0.00 to 2.00 (s)
range

5-5-4 Setting Frequency References through Key Sequences

The following description provides information on parameters related to frequency ref-
erence settings through key sequences on the Digital Operator
H Setting Frequency References 1 through 8 and the Inching Frequency
Command (n21 through n28 and n29)
A total of nine frequency references (frequency references 1 through 8) and an inching frequency com-
mand can be set together in the Inverter.
D Setting Frequency References 1 through 8 (n21 through n28)
n21
Frequency Reference 1
Setting
0.0 to max. frequency
range
n22
Frequency Reference 2
Setting
0.0 to max. frequency
range
n23
Frequency Reference 3
Setting
0.0 to max. frequency
range
n24
Frequency Reference 4
Setting
0.0 to max. frequency
range
n25
Frequency Reference 5
Setting
0.0 to max. frequency
range
5-10
Unit of
1%
setting
Unit of
0.01 s
setting
Unit of
0.01 Hz (see
setting
note 1)
Unit of
0.01 Hz (see
setting
note 1)
Unit of
0.01 Hz (see
setting
note 1)
Unit of
0.01 Hz (see
setting
note 1)
Unit of
0.01 Hz (see
setting
note 1)
Chapter 5
Changes during
operation
Default setting
Changes during
No
operation
Default setting
0.10
Changes during
operation
Default setting
Changes during
operation
Default setting
Changes during
operation
Default setting
Changes during
operation
Default setting
Changes during
operation
Default setting
Yes
0
Yes
6.0
Yes
0.0
Yes
0.0
Yes
0.0
Yes
0.0