Advanced Operation
n62
Frequency Hold Function Selector
Setting
0, 1
range
Set Values
Value
0
The frequency on hold is not retained.
1
The frequency on hold for 5 s or more is retailed.
Operation of UP/DOWN Function
RUN command
(Forward rotation)
UP command
(S4)
DOWN command
(S5)
Output frequency
Upper limit
Lower limit
Status
Frequency
detection
Note Status
• The following ON/OFF combinations of UP and DOWN commands are possible.
Command
S4 (UP command)
S5 (DOWN command)
• With the UP/DOWN function used, the output frequency has the following restrictions for upper and
lower limits.
Upper limit:
The maximum frequency in n09 or the frequency reference upper limit in n30, which-
ever is smaller.
Lower limit:
The minimum output frequency in n14 or frequency reference lower limit in n31,
whichever is smaller.
6-20
Unit of
setting
U: UP (acceleration)
D: DOWN (deceleration)
H: Hold
U1: Frequency acceleration restricted by upper limit.
D1: Frequency deceleration restricted by lower limit.
Acceleration
Deceleration
ON
OFF
OFF
ON
Changes during
operation
1
Default setting
Description
Hold
OFF
OFF
Chapter 6
No
0
Time
Time
Time
Time
Time
Hold
ON
ON