Table 10
Fault Symptom Codes (continued)
FSC
Message
5014
Drive Already Loaded
(Cleaning operation failed because the
drive already has a cartridge inserted.)
5015
Expired Clean'g Cart
(Cleaning operation failed due to an
expired cleaning cartridge.)
5016
Not a Clean'g Cart
(Cleaning operation failed because the
loaded cartridge is not a cleaning
cartridge.)
5035
Drive Timeout Error
(Cleaning operation failed because the
drive timed out.)
503B
Move Command Fail
(A front panel move operation failed.)
503C
Clean Operation Timeout
(Cleaning operation failed because the
drive timed out.)
ERP
Press the Enter button to clear the
message.
Invalid user initiated operation. Set
parameters correctly and try again.
If the tape in the drive is not in use,
unload the drive and retry the cleaning
operation.
Press the Enter button to clear the
message.
Remove expired cleaning cartridge from
library and discard. Replace with new
cleaning cartridge.
Press the Enter button to clear the
message.
Make sure tape in reserved slot is a
cleaning cartridge.
Invalid user initiated operation. Set
parameters correctly and try again.
Press the Enter button to clear the
message.
Invalid user initiated operation. Set
parameters correctly and try again.
Ensure the drive shows good status
through the drive status window.
Press the Enter button to clear the
message.
Invalid user initiated operation. Set
parameters correctly and try again.
Press the Enter button to clear the
message.
Invalid user initiated operation. Set
parameters correctly and try again.
Ensure the drive shows good status
through the drive status window.