Table 10
Fault Symptom Codes (continued)
FSC
Message
3300
Rotary Jammed
(Rotary track could not reach target
location.)
3301
Shuttle on Wrong Side Of The Rotary
(Zone indicators show that the shuttle is
backwards on the rotary track during
power-up initialization.)
3303
Shuttle Not Attached to Cable
3400
Pass-through Elevator Jammed
(Pass-through shuttle could not reach
target location.)
3500
Vertical Elevator Jammed
(Vertical elevator could not reach target
location. 10U libraries only).
5011
All Slots Empty
(There are no cartridges installed in any
of the reserved cleaning slots.)
124
Troubleshooting
ERP
Press the Enter button to reboot.
Cycle power to the library or reboot
using the GUI touch screen.
Ensure that there are no obstructions
inside the library (all cartridges are in
magazines).
Ensure cartridges are fully inserted in the
magazine(s).
Press the Enter button to reboot.
Cycle power to the library or reboot
using the GUI touch screen.
Cycle power to the library or reboot by
using the LCD touch display.
Check cable connections.
Press the Enter button to reboot.
Cycle power to the library or reboot
using the GUI touch screen.
Ensure that there are no obstructions
inside the library (all cartridges are in
magazines).
Check pass-through alignment.
Press the Enter button to reboot.
Cycle power to the library or reboot
using the GUI touch screen.
Ensure that there are no obstructions
inside the library (all cartridges are in
magazines).
Press the Enter button to clear the
message.
Insert cleaning cartridge in reserved
cleaning slot.
Invalid user initiated operation. Set
parameters correctly and try again.