Table 10
Fault Symptom Codes (continued)
FSC
Message
3075
Drive 1 Eject Failed
(Eject command time-out.)
3076
Drive 2 Eject Failed
(Eject command time-out.)
3077
Drive 3 Eject Fail
(Eject command time-out.)
ERP
Press the Enter button to reboot.
•
•
Ensure the drive shows good status
through the drive status window.
•
Deactivate the drive using the GUI control
panel maintenance menu.
•
Reseat drive.
•
Load/unload a cartridge to the drive to
verify.
•
Check the tape cartridge used in the last
operation for damage.
•
Run the cartridge cycle diagnostic to
verify.
Press the Enter button to reboot.
•
•
Ensure the drive shows good status
through the drive status window.
•
Deactivate the drive using the GUI control
panel maintenance menu.
Reseat drive.
•
•
Load/unload a cartridge to the drive to
verify.
•
Check the tape cartridge used in the last
operation for damage.
•
Run the cartridge cycle diagnostic to
verify.
Press the Enter button to reboot.
•
•
Ensure the drive shows good status
through the drive status window.
•
Deactivate the drive using the GUI control
panel maintenance menu.
•
Reseat drive.
•
Load/unload a cartridge to the drive to
verify.
•
Check the tape cartridge used in the last
operation for damage.
•
Run the cartridge cycle diagnostic to
verify.
MSL6000 series tape library user guide 117