HP MSL6000 Series User Manual page 116

Storageworks msl6000 series storage tape library
Hide thumbs Also See for MSL6000 Series:
Table of Contents

Advertisement

Table 10
Fault Symptom Codes (continued)
FSC
Message
305B
Diag Fetch, Drive not loaded
(Diag: no cartridge present for fetch.)
305D
Diag Timeout waiting for drive empty,
ready
(Fetch, time-out waiting for drive unload.)
305F
Invalid bin number
(Invalid bin number detected in diag.)
3060
Zone Sequence Error
(Robot did not find sensor on power-up.)
3074
Drive 0 Eject Failed
(Eject command time-out.)
116
Troubleshooting
ERP
Press the Enter button to clear the
message.
Load a cartridge in the drive and retry
the operation.
Invalid user initiated operation. Set
parameters correctly and try again.
Press the Enter button to reboot.
Invalid user initiated operation. Set
parameters correctly and try again.
Ensure the drive shows good status
through the drive status window.
Check the tape cartridge used in the last
operation for damage.
Press the Enter button to clear the
message.
Invalid user initiated operation. Set
parameters correctly and try again.
Cycle power to the library or reboot
using the GUI touch screen.
Press the Enter button to reboot.
Ensure the drive shows good status
through the drive status window.
Deactivate the drive using the GUI control
panel maintenance menu.
Reseat drive.
Load/unload a cartridge to the drive to
verify.
Check the tape cartridge used in the last
operation for damage.
Run the cartridge cycle diagnostic to
verify.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents