AMX Optima Instruction Manual page 32

Distribution matrix
Hide thumbs Also See for Optima:
Table of Contents

Advertisement

Installation and Setup
Linking an Optima Using a Media Converter and Multi-Port Switch
Linking an Optima enclosure to multiple other types of enclosures (other than linking in a daisy chain off
an enclosure with a 10Base-2 / BNC connector) requires a Multi-Port Switch and RJ-45 straight-through
patch cables. Depending on the other types of enclosures, a Media converter(s) and RG-58 coax cable(s)
may also be required. FIG. 11 shows a system with two Optima enclosures and a Modula enclosure
linked using a 5-Port Switch and a Media Converter.
Cable Length Requirements
Network Segment
Optima to Multi-Port Switch
Multi-Port Switch directly to another type enclosure RJ-45 straight-through patch
Multi-Port Switch to Media Converter
Media Converter to last enclosure in daisy chain
Note: If you have questions regarding cabling or network related issues in conjunction with using a
Multi-Port Switch (or hub) for linking enclosures, contact your network administrator.
When attaching multiple enclosures to a Multi-Port Switch, one or more can be connected directly to
the Multi-Port Switch (see steps below) and/or one or more can use a Media Converter to connect to
the Multi-Port Switch (see steps on page 27). In a system with multiple 10Base-2 enclosures, only one
needs to be attached to the Multi-Port Switch with a Media Converter. The rest can be daisy-chained.
To link an Optima enclosure to a Multi-Port Switch:
1.
Insert one end of the RJ-45 straight-through patch cable into the Enc Link (RJ-45) Ethernet port on
the Optima enclosure.
2.
Insert the other end of the RJ-45 straight-through patch cable into the Multi-Port Switch.
3.
Repeat Steps 1 and 2 for enclosures with 10Base-T ports.* For 10Base-2 ports, see page 27.**
* Applies when linking an Optima, an Optima SD, a Precis SD, or an Epica DG to a Multi-Port Switch.
** Applies when linking a Modula, Modula CatPro, Epica-128, or Epica-256
5-Port Switch
Straight-Through
Patch Cable
FIG. 11
Two Optima enclosures linked to a Modula enclosure
26
Cable Type
RJ-45 straight-through patch
RJ-45 straight-through patch
RG-58 coax
Straight-Through Patch Cable
Straight-Through Patch Cable
Media Converter
Maximum Distance
100 ft. (30.5 m)
100 ft. (30.5 m)
100 ft. (30.5 m)
10 ft. (3.05 m) total
.
50-ohm Termination Connectors
RG-58 Coax Cable
The total length of all cables between
the Media Converter and the last
enclosure in a daisy chain cannot
exceed 10 ft. (3.05 m).