AMX Optima Instruction Manual page 30

Distribution matrix
Hide thumbs Also See for Optima:
Table of Contents

Advertisement

Installation and Setup
Linking an Optima to Another Enclosure with an RJ-45 Ethernet Port
An Optima can be directly linked to another Optima, an Optima SD, a Precis SD, an Epica DG,
an Epica DGX 32, or an Epica DGX 144 via the RJ-45 Ethernet ports.
The total distance between the two linked enclosures cannot exceed 100 ft. (30.5 m).
Cable Length Requirements
Network Segment
Optima to Optima or Optima SD or Precis SD or
Epica DG or Epic DGX 32 or Epica DGX 144
To link an Optima to another enclosure with an RJ-45 Ethernet port:
1.
Insert one end of the crossover cable into the first Optima's Enc Link (RJ-45) port.
2.
Insert the other end of the crossover cable into the Enc Link (RJ-45) port on the second Optima
(Optima SD, Precis SD, Epica DG, Epica DGX 32, or Epica DGX 144).
System & Enclosure Numbers
FIG. 9
Optima 3 RU linked to an Optima 2 RU
When power is applied, the Ethernet connector LEDs illuminate indicating communication status
(see page 23).
24
Cable Type
Maximum Distance
RJ-45 crossover
100 ft. (30.5 m)
RJ-45 Crossover Cable
Max. 100 ft. (30.5 m)
Optima Instruction Manual