Heatsink Load Metrology
D
Heatsink Load Metrology
To ensure compliance to max socket loading value listed in Table 4-3, and to meet the
performance targets for Thermal Interface Material in Section 5.3, the Heatsink Static
Compressive Load can be assessed using the items listed below:
• HP34970A DAQ
• Omegadyne load cell, 100 lbf max (LCKD-100)
• Test board (0.062") with ILM & back plate installed
• 8 in-lbf pneumatic driver
• Heatsink
• Gainestown Load Cell Fixture
Thermal/Mechanical Design Guide
(Figure
D-1)
85