The Remote Policies screen for an Entry Channel Hub type allows the SCPC
data rates and switch types to be specified for when the Remotes will switch and
the desired starting points for communications.
Figure 3-22
Entry Channel Switch Rates screen
Entering the Remote number at the command prompt in figure 3-22 allows the
SCPC Data Rate and the Switch Type for that Remote to be set, as shown in
figure 3-23. Switch type 0 corresponds to Load Switching; switch types 64
through 255 are user-defined, and must match VMS policies. When choosing
Load Switching as the Switch Type, the associated Remote must have the Load
Switching feature Enabled (see the section "STDMA/SCPC Automatic Switch-
ing" on page 3-27).
Figure 3-23
Remote SCPC Data Rate and Switch Type prompt
The Global SCPC Rate command can be used to set the data rate for all or a
majority of the Remotes. This allows the rate to be entered just once instead of
entering the rate for each remote individually. Enter G at the command prompt.