Setting In The Utility Mode - Minolta CF2002 Service Manual

Cf2002; cf3102
Hide thumbs Also See for CF2002:
Table of Contents

Advertisement

3-3.

Setting in the Utility Mode

Meter Count
Purpose
To check the count of each counter or
print a list of counters.
User's Choice: 1
<1/2>
Item
To set the time-of-day, date, and
time zone and start the clock.
Date/Time Set
To select whether to permit recall-
Memory
ing and copying of image data
Recall
which has previously been sub-
jected to a copy cycle.
<2/2>
Item
To set the time it takes the printer
to enter the Energy Saver mode
Energy Saver
after a print cycle has been com-
pleted or the last key operated.
To set the time it takes the printer
to enter the Sleep mode after a
print cycle has been completed or
the last key operated.
In the Sleep mode, only the 5-V
Sleep
line remains ON.
• To print the list, load the 1st Drawer with A4
lengthwise or Letter lengthwise paper.
• The printer rejects the print cycle if the drawer is
loaded with paper of any other size.
Purpose
Purpose
S-12
Setting/Precautions
Setting/Precautions
• The default setting is 00:00, January
1, 2000.
• For the time zone, set the time differ-
ence from the Greenwich Mean
Time.
The default setting is Yes.
Yes
Setting/Precautions
• Use the 10-Key Pad to enter the time
(10 to 240 min.).
• The default setting is 15 min.
15 min (10 to 240)
• Use the 10-Key Pad to enter the time
(15 to 240 min.).
• The default setting is 30 min.
30 min (15 to 240)
• The option of "No" becomes avail-
able only if "Yes" is selected for "Dis-
able Sleep Mode" of the "Admin.
Mode."
No

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cf3102

Table of Contents