1-2.
Setting up the Service Jig
NOTE
• Before attempting to set, adjust, or check the printer, set up the Service Jig by following
the procedure given below.
• Do not turn on any equipment until you are instructed to do so.
1. Remove the two screws from the selector, and
then remove the upper cover.
4004D295AA
2. Affix the aluminum tape to the Selector as illus-
trated and replace the cover removed in step 1.
4004D296AA
3. Using a DTP32 cross-cable, connect the I/O port
of the X-Rite to port B of the selector.
C4004U559AA
4. Using the RS232 straight cable (2), connect the
COM 1 port of the computer to port C on the
selector.
NOTE
• When connecting to the COM2 port, set the Exter-
nal Panel Controller port setting to COM2.
C4581U022AA
D-2