"P" Group: Expansion Card Functions

"P" Function
Func.
Name
Code
P001
Operation mode on
expansion card 1 error
P002
Operation mode on
expansion card 2 error
P010
Feedback option enable
P011
Encoder pulse-per-
revolution (PPR) setting
P012
Control pulse setting
P013
Pulse input mode setting Pulse input mode setting.
P014
Home search stop
position setting
P015
Home search speed
setting
P016
Home search direction
setting
P017
Home search comple-
tion range setting
P018
Home search comple-
tion delay time setting
P019
Electronic gear set
position selection
P020
Electronic gear ratio
numerator setting
P021
Electronic gear ratio
denominator setting
The two (optional) expansion cards for the SJ300 have associated configuration data. The
following table defines the functions and their value ranges. Please refer to the expansion card
manual for more details.
Description
Two option codes:
00 Trip (stop motor)
01 Continuous operation
Two option codes:
00 Trip (stop motor)
01 Continuous operation
Two option codes:
00 Disable
01 Enable
Range is 128 to 65000
pulses per revolution
Selects between automatic
speed regulation (ASR) and
automatic position regula-
tion (APR) modes.
Two option codes:
00 ASR mode
01 APR mode
Three option codes:
00 quadrature
01 count and direction
02 separate forward and
reverse pulse trains
Range is 0 to 4095 pulses
Range is 0.00 to 99.99 /
100.0 to 120.0Hz
Two option codes:
00 Forward
01 Reverse
Range is 0 to 10,000 pulses
Range is 0.00 to 9.99
seconds
Two option codes:
00 Position feedback side
01 Position command side
Range is 1 to 9999
Range is 1 to 9999
Defaults
Run
Mode
Edit
–FE
–FU
–FR
Lo Hi
(EU)
(US)
(JP)
✘ ✔
00
00
00
✘ ✔
00
00
00
✘ ✘
00
00
00
✘ ✘
1024 1024 1024 pulse
✘ ✘
00
00
00
✘ ✘
00
00
00
✘ ✔
0.
0.
0.
✘ ✔
5.00
5.00
5.00
✘ ✘
00
00
00
✘ ✔
5
5
5
✘ ✔
0.00
0.00
0.00
✘ ✔
00
00
00
✘ ✔
1.
1.
1.
✘ ✔
1.
1.
1.
3–65
SJ300 Inverter
SRW Display
Units
>P001 OPTION1
SELECT
TRP
>P002 OPTION2
SELECT
TRP
>P010 FEEDBACK
SELECT
OFF
>P011 FEEDBACK
ENC-P
01024pls
>P012 FEEDBACK
CONTROL
ASR
>P013 FEEDBACK
PULSE
MD0
>P014 FEEDBACK
POS
0000pls
Hz
>P015 FEEDBACK
FC
005.00Hz
>P016 FEEDBACK
TURN
FW
pulse
>P017 FEEDBACK
L
00005pls
sec.
>P018 FEEDBACK
TW
000.00s
>P019 FEEDBACK
EGRP
FB
>P020 FEEDBACK
EGR-N
00001
>P021 FEEDBACK
EGR-D
00001