Download Print this page
Hitachi SJ300 Specifications
Hide thumbs Also See for SJ300:

Advertisement

SJ300 Inverter Specifications

SJ300 Inverter Specifications
Tables for 200V
Note that "General Specifications" on page 1–9 covers all SJ300 inverters, followed by
footnotes for all specifications tables. The 200V models in the upper table below (1/2 to 15 hp)
class inverters
include internal dynamic braking units (see "Dynamic Braking" on page 5–6).
Item
SJ300 inverters, 200V models, UL version
Applicable motor size, 4-pole *2
Rated capacity (200/240V) kVA
Rated input voltage
Rated input current (A)
Rated output voltage *3
Rated output current (A)
Efficiency at 100% rated output, %
Watt loss,
at 70% output
approximate (W)
at 100% output
Starting torque *6
Dynamic braking
internal res. only
approx. % torque,
with external res.
short time stop *7
DC braking
Weight
kg / lb
Item
SJ300 inverters, 200V models, UL version
Applicable motor size *2
Rated capacity (200/240V) kVA
Rated input voltage
Rated input current (A)
Rated output voltage *3
Rated output current (A)
Efficiency at 100% rated output, %
Watt loss,
at 70% output
approximate (W)
at 100% output
Starting torque *6
Dynamic braking
w/o braking unit
approx. % torque,
with braking unit
short time stop *7
DC braking
Weight
kg / lb
004LFU
007LFU
015LFU
HP
1/2
1
2
kW
0.4
0.75
1.5
1.0 / 1.2
1.7 / 2.0
2.5 / 3.1
3-phase: 200 to 240V ±10%, 50/60 Hz ±5%
3.8
5.5
8.3
3-phase (3-wire) 200 to 240V (corresponding to input voltage)
3.0
5.0
7.5
85.1
89.5
92.3
64
76
102
70
88
125
200% at 0.5 Hz (SLV), 150% at around 0 Hz (SLV, 0 Hz domain,
with motor one frame size down), 100% at 0 Hz (with feedback board)
50%
200%
Variable operating frequency, time, and braking force
3.5 / 7.7
3.5 / 7.7
3.5 / 7.7
200V Class Specifications, continued
150LFU
185LFU
HP
20
25
kW
15
18.5
22.1 / 26.6 26.3 / 31.5 32.9 / 39.4 41.9 / 50.2
3-phase: 200 to 240V ±10%, 50/60 Hz ±5%
70
84
3-phase (3-wire) 200 to 240V (corresponding to input voltage)
64
76
94.9
95.0
575
698
800
975
200% at 0.5 Hz (SLV), 150% at around 0 Hz (SLV, 0 Hz domain,
with motor one frame size down), 100% at 0 Hz (with feedback board)
30–200%
25–170%
Variable operating frequency, time, and braking force
12 / 26.4
12 / 26.4
200V Class Specifications
022LFU
037LFU
055LFU
3
5
7.5
2.2
3.7
5.5
3.6 / 4.3
5.7 / 6.8
8.3 / 9.9
12
18
26
10.5
16.5
24
93.2
94.0
94.4
127
179
242
160
235
325
20%
160%
100%
3.5 / 7.7
3.5 / 7.7
3.5 / 7.7
220LFU
300LFU
370LFU
30
40
50
22
30
37
50.2/60.2
105
133
160
95
121
145
95.0
95.1
95.1
820
1100
1345
1150
1550
1900
10%
25–150%
55–110%
45–90%
12 / 26.4
20 / 44
30 / 66
075LFU
110LFU
10
15
7.5
11
11 / 13.3
15.9/
19.1
35
51
32
46
94.6
94.8
312
435
425
600
10%
80%
70%
5 / 11
5 / 11
450LFU
550LFU
60
75
45
55
63 / 75.6
76.2/91.4
200
242
182
220
95.1
95.1
1625
1975
2300
2800
35–75%
30–60%
30 / 66
50 / 110

Advertisement

loading

Summary of Contents for Hitachi SJ300

  • Page 1: Sj300 Inverter Specifications

    SJ300 Inverter Specifications SJ300 Inverter Specifications Tables for 200V Note that “General Specifications” on page 1–9 covers all SJ300 inverters, followed by footnotes for all specifications tables. The 200V models in the upper table below (1/2 to 15 hp) class inverters include internal dynamic braking units (see “Dynamic Braking”...
  • Page 2 SJ300 Inverter Tables for 400V Note that “General Specifications” on page 1–9 covers all SJ300 inverters, followed by class inverters footnotes for all specifications tables. The 400V models in the upper table below (1 to 15 hp) include internal dynamic braking units (see “Dynamic Braking” on page 5–6). Item 400V Class Specifications SJ300 inverters,...
  • Page 3 Note 5: When SLV is selected, please set the carrier frequency higher than 2.1 kHz. Note 6: At the rated voltage when using a Hitachi standard 3-phase, 4-pole motor (when selecting sensorless vector control—SLV). Note 7: The braking torque via capacitive feedback is the average deceleration torque at the shortest deceleration (stopping from 50/60 Hz as indicated).
  • Page 4: General Specifications

    SJ300 Inverter General The following table (continued on next page) applies to all SJ300 inverter models. Specifications Item General Specifications Protective enclosure *1, *11 IP20 (NEMA 1) Control method Line-to-line sine wave pulse-width modulation (PWM) control Output frequency range *4 0.1 to 400 Hz Frequency accuracy Digital command: ±...
  • Page 5 SJ300 Inverter Specifications Item General Specifications Other user-settable parameters V/F free-setting (up to 7 points), frequency upper/lower limit, frequency jump, accel/ decel curve selection, manual torque boost value and frequency adjustment, analog meter tuning, start frequency, carrier frequency, electronic thermal protection level, external frequency output zero/span reference, external frequency input bias start/end, analog input selection, retry after trip, restart after instantaneous power failure, various signal outputs, reduced voltage start, overload restriction, default value setting (US,...
  • Page 6: Derating Curves

    SJ300 Inverter Derating Curves The maximum available inverter current output is limited by the carrier frequency and ambient temperature. The carrier frequency is the inverter’s internal power switching frequency, settable from 0.5 kHz to 12 kHz. Choosing a higher carrier frequency tends to decrease audible noise, but it also increases the internal heating of the inverter, thus decreasing (derating) the maximum current output capability.
  • Page 7 SJ300 Inverter Specifications Derating curves, continued... SJ300 30 to 55 kW at 50 deg. C ambient, continued 015 to 185H 100% 370H 450H 220H 300H 550H 14 15 Carrier Frequency (kHz) SJ300 75 to 150 kW at 50 deg. C ambient 100% 750H 900H...