Hitachi SJ300 Series Instruction Manual page 132

Hitachi instruction manual inverter sj300 series
Hide thumbs Also See for SJ300 Series:
Table of Contents

Advertisement

3–64
"H" Group: Motor Constants Functions
Func.
Name
Code
H224 Motor constant J,
2nd motor
H030 Auto-tuned motor
constant R1, 1st motor
H230 Auto-tuned motor
constant R1, 2nd motor
H031 Auto-tuned motor
constant R2, 1st motor
H231 Auto-tuned motor
constant R2, 2nd motor
H032 Auto-tuned motor
constant L, 1st motor
H232 Auto-tuned motor
constant L, 2nd motor
H033 Auto-tuned motor
constant I
, 1st motor
0
H233 Auto-tuned motor
constant I
, 2nd motor
0
H034 Auto-tuned motor
constant J, 1st motor
H234 Auto constant J,
2nd motor
H050 PI proportional gain for
1st motor
H250 PI proportional gain for
2nd motor
H051 PI integral gain for 1st
motor
H251 PI integral gain for 2nd
motor
H052 P proportional gain
setting for 1st motor
H252 P proportional gain
setting for 2nd motor
H060 0Hz SLV limit for 1st
motor
H260 0Hz SLV limit for 2nd
motor
H070 Terminal selection PI
proportional gain setting
H071 Terminal selection PI
integral gain setting
H072 Terminal selection P
proportional gain setting
"H" Function
Description
Ratio (unit-less), range is
1.0 to 1000
Auto-tuning data
Auto-tuning data
Auto-tuning data
Auto-tuning data
Auto-tuning data
Auto-tuning data
Auto-tuning data
Auto-tuning data
Auto-tuning data
Auto-tuning data
Range is 0.0 to 99.9 / 100.0
to 999.9 / 1000%
Range is 0.0 to 99.9 / 100.0
to 999.9 / 1000%
Range is 0.0 to 99.9 / 100.0
to 999.9 / 1000%
Range is 0.0 to 99.9 / 100.0
to 999.9 / 1000%
Range is 0.00 to 10.00
Range is 0.00 to 10.00
Range is 0.0 to 100.0%
Range is 0 to 100.0%
Range is 0 to 99.9 / 100.0 to
999.9 / 1000%
Range is 0 to 99.9 / 100.0 to
999.9 / 1000%
Range is 0.00 to 10.00
Defaults
Run
Mode
Edit
–FE
–FU
–FR
Lo Hi
(EU)
(US)
(JP)
✘ ✘
According to
inverter rating
✘ ✘
According to
inverter rating
✘ ✘
According to
inverter rating
✘ ✘
According to
inverter rating
✘ ✘
According to
inverter rating
✘ ✘
According to
inverter rating
✘ ✘
According to
inverter rating
✘ ✘
According to
inverter rating
✘ ✘
According to
inverter rating
✘ ✘
According to
inverter rating
✘ ✘
According to
inverter rating
✔ ✔
100
100
100
✔ ✔
100
100
100
✔ ✔
100
100
100
✔ ✔
100
100
100
✔ ✔
1.00
1.00
1.00
✔ ✔
1.00
1.00
1.00
✔ ✔
100.
100.
100.
✔ ✔
100.
100.
100.
✔ ✔
100.0 100.0 100.0
✔ ✔
100.0 100.0 100.0
✔ ✔
1.00
1.00
1.00
SRW Display
Units
>H224 2AUX
J
000.055
Ohm
>H030 AUX
A-R1
00.489ohm
Ohm
>H230 2AUX
A-R1
00.489ohm
Ohm
>H031 AUX
A-R2
00.355ohm
Ohm
>H231 2AUX
A-R2
00.355ohm
mH
>H032 AUX
A-L
005.12mH
mH
>H232 2AUX
A-L
005.12mH
A
>H033 AUX
A-I0
008.02A
A
>H233 2AUX
A-I0
008.02A
>H034 AUX
A-J
0000.055
>H234 2AUX
A-J
0000.055
%
>H050 AUX
KSP
0100.0%
%
>H250 2AUX
KSP
0100.0%
%
>H051 AUX
KSI
0100.0%
%
>H251 2AUX
KSI
0100.0%
>H052 AUX
KSPP
001.00
>H252 2AUX
KSPP
001.00
%
>H060 AUX
0SLV-LMT
100.0%
%
>H260 2AUX
0SLV-LMT
100.0%
%
>H070 AUX
CH-KSP
0100.0%
%
>H071 AUX
CH-KSI
0100.0%
>H072 AUX
CH-KSPP
001.00

Advertisement

Table of Contents
loading

Table of Contents