Hitachi SJ300 Series Instruction Manual page 103

Hitachi instruction manual inverter sj300 series
Hide thumbs Also See for SJ300 Series:
Table of Contents

Advertisement

"B" Function
Func.
Name
Code
B025 Overload restriction
setting (2)
B026 Deceleration rate at
overload restriction (2)
Description
Sets the level for overload
restriction (2), between 50%
and 200% of the rated
current of the inverter,
setting resolution is 1% of
rated current
Sets the deceleration rate (2)
when inverter detects
overload, range is 0.1 to
30.0, resolution is 0.1.
NOTE: Two sets of overload restriction parameters are available. The set that is in use may be
selected by means of an intelligent input terminal (see
Defaults
Run
Mode
Edit
–FE
–FU
–FR
Lo Hi
(EU)
(US)
(JP)
✘ ✔
rated current times
1.50
✘ ✔
1.00
1.00
1.00
"Overload Restriction" on page
3–35
SJ300 Inverter
SRW Display
Units
A
>b025 OLOAD
2LEVEL
0024.8A
sec.
>b026 OLOAD
2CONST
01.00
4–35).