Command – 07 - Hitachi SJ300 Series Instruction Manual

Hitachi instruction manual inverter sj300 series
Hide thumbs Also See for SJ300 Series:
Table of Contents

Advertisement

B–14
Communications Protocol
Command – 07
The 07 command sets a parameter value equal to the value specified in the transmission.The
frame format of command 07 follows the diagram and specification table.
Frame format
STX Node
Element
Description
STX
Control code (STart of TeXt)
Node
Node (station) address of inverter
Command
Transmission command
Parameter
Function code of parameter
Data
Transmission data
BCC
Block check sum code
[CR]
Control code (carriage return)
Note that the parameter F001, the output frequency, can be set more directly with host
command 01 instead of with this command. Use the codes in the following table for setting
parameters associated with H003 and H203.
Code Data
00
U.S. mode (B85=00, 02) 0.2 kW
EU mode (B85=01)
0.2 kW
Code Data
11
U.S. mode (B85=00, 02) 5.5 kW
EU mode (B85=01)
5.5 kW
Command
Parameter
Data
Size
1 byte
2 bytes 01 to 32, and FF (broadcast to all
2 bytes 07
4 bytes F002..., A001..., B001..., C001...,
8 bytes Value of parameter times ten as
2 bytes Exclusive OR of Node,
1 byte
01
02
03
04
0.4
0.75
0.37
0.55 0.75
12
13
14
15
7.5
11
15
18.5
7.5
11
15
18.5
BCC [CR]
Value
STX (0x02)
nodes)
H003..., P001...
ASCII char. code, except for
H003 and H203 (see table below)
Command, and Data
[CR] (0x0D)
05
06
07
08
09
1.5
2.,2
3.7
1.1
1.5
2.2
3.0
16
17
18
19
20
22
30
37
45
55
22
30
37
45
55
10
4.0
21
75
75