Hitachi SJ300 Series Instruction Manual page 260

Hitachi instruction manual inverter sj300 series
Hide thumbs Also See for SJ300 Series:
Table of Contents

Advertisement

B–12
Communications Protocol
For Command 05, bytes 2, 3, and 4 of
the event history are status codes A, B,
and C, respectively. The tables below
provide status code descriptions.
Code
Status A Definition
00
Initial status
01
02
On Stopping
03
On running
04
On free-run stop
05
On jog
06
On dynamic braking
07
On retry
08
On trip
09
On under-voltage
Bit
Status B Definition
0
Ground fault
1
IGBT error, U phase
2
Under-voltage error
3
Over-voltage protection
4
Thermal trip
5
IGBT error, V phase
6
IGBT error, W phase
7
Gate array error
Data field contents
byte 2
byte 3
Status A
Status B
Status C Definition
On reset
On stopping
On deceleration
Constant speed
On acceleration
On 0 Hz running
On running
On dynamic braking
On overload restriction
Error
Code
E14
E30
E09
E07
E21
E30
E30
E23
byte 4
Status C

Advertisement