Message Format For Forwarding Syslog - Fujitsu XG2000 Series User Manual

Xg2000 series compact, 20-port 10 gigabit ethernet layer 2 switch
Hide thumbs Also See for XG2000 Series:
Table of Contents

Advertisement

XG2000 series User's Guide
A.3

Message Format for Forwarding syslog

The logs output from the device can be forwarded to a syslog server. The device forwards logs in a message format that
conforms to the RFC3164 The BSD Syslog Protocol.
The format the device uses to forward a syslog message to the syslog server is shown below.
Format of syslog message
in XG2000 series
Priority
Time
Host name
Device type
Function type
Severity
Message ID
Message
The device appends the Priority value at the beginning of the log message then inserts the Device type between the Host
name and the Function type before forwarding the message to the specified syslog server.
The Priority value is used to identify the severity and facility of a log message.
It is added according to the following rules.
Priority must have three, four, or five characters. It starts with an angle bracket "<", followed by a number, followed by
an angle bracket ">". Example: <14>
The Priority value is calculated from the Facility code (Facility) and the Severity code (Severity). The Priority value
consists of one, two, or three decimal integers.
The Priority value is calculated by first multiplying the Facility code by 8 and then adding the numerical value of the
Severity code.
The Facility code defined in the device is:
Facility code
1
The Severity codes defined in the device are:
Severity code
2
3
4
6
Description
Priority string
The time the message was generated
(MM:DD:HH:MM:SS)
Host name of the device
XG
Abbreviated name for the control that output the
message.
Severity of the message
The code that uniquely identifies the message
Message text
random user-level messages
Critical : critical conditions
Error : error conditions
Warning : warning conditions
Informational : informational messages
300/315
All Rights Reserved, Copyright (C) PFU LIMITED 2009
Format of syslog message in
PRI part
HEADER part
MSG part
Type of Facility
Description of Severity
RFC3164
Priority
TimeStamp
HostName
Tag