Pilot Head
Orifice
Figure 16. Pilot orifice removal and replacement.
15. Install the new regulator: Be sure the new gasket is
properly positioned and tighten screws securely.
16. Install the identification labels to the stove so that
they can be seen by any person that may be servicing
the stove.
Label A: apply to back of stove.
Label B: apply to stove's rating plate.
Small valve Label: apply to valve.
17. Reassemble the stove, apply gas to the system and
check for leaks using a soapy water solution or elec-
tronic gas detector.
NEVER USE AN OPEN FLAME TO CHECK FOR GAS LEAKS.
18.Correct gas pressure is essential for efficient and safe
operation of this appliance. Use a manometer to check
pressures as specified in the Gas Pressure section of
this manual (page 15).
19. Adjust the Air Shutter. You will need to position the
shutter to provide a gas/air mixture that will achieve
the best flame picture with your particular installation.
Start with the shutter stem at the half-way position in
the slot in the bottom of the stove. See fig. 12. Pushing
the stem back will restrict air, while pushing it for-
ward will open the shutter and increase air. With some
experimentation, you will find the shutter position that
works best for your installation.
ALWAYS REFER TO THE LIGHTING INSTRUCTIONS ON THE
INSIDE BACK COVER OF THIS MANUAL WHEN LIGHTING
YOUR STOVE.
Retainer Clip
Pilot Base

Gas Supply Connection

The gas supply line connection is made to the left side of
the front-mounted valve. The gas supply line should be
3/8" npt with a 1/2" diameter supply, or the appropriate
size to provide sufficient gas pressure to the valve regard-
less of the input setting.
ceptable in many areas in the U.S. However, Canadian
methods vary depending on local code.
OR IN THE ABSENCE OF LOCAL CODE, MUST COMPLY WITH
THE MOST RECENT EDITION OF THE NATIONAL FUEL GAS
CODE ANSI Z223.1/NFPA 54 OR CAN-B149.
union, to be installed in the supply line, and in the same
room as the appliance. This allows for the disconnection
of the stove for servicing and maintenance. See fig. 18.
sealing compounds. For propane units be sure to use
compounds that are propane resistant. Turn on gas sup-
ply and test for gas leaks using a soapy water solution or
electronic gas detector. Never use an open flame to check
for leaks.
Apply small conversion label.
Valve
Figure 17. Regulator assembly.
BLOWER NOTE: Install the optional blower before con-
necting the gas line in order to ensure adequate clear-
ance between both.
The use of Flexible Gas Appliance Connectors is ac-
ALL INSTALLATIONS MUST COMPLY WITH LOCAL CODE
All codes require a gas shut-off valve (gas cock) and
A T-HANDLE GAS COCK IS REQUIRED IN
MASSACHUSETTS TO COMPLY WITH CODE 248CMR.
Secure all joints tightly using appropriate tools and
138301_Rev_G 10.4.11