4-1-2
Overview of Each Mode
Monitor Mode A
In this mode, one "d" group Inverter monitor function and one
"F to U" group Inverter parameter are displayed on the same
screen.
The content of "d" group Inverter monitor function is displayed
in a large font size. The parameter number such as "F001" and
the content of "F to U" parameter are displayed without the
function name.
Monitor Mode B
In this mode, four "d" group Inverter
monitor functions can be displayed on the same screen.
At this time, the parameter numbers are not displayed.
LCD Digital Operator User's Manual (I579)
These modes can be called at any level and in any operating state.
Press the ESC key to restore the operating state before the call.
Read
Write
Mode
Mode
4 Operation Procedures
Option
Press three keys
simultaneously.
Mode
Option
Select the setting item.
Mode
Option
Change the set values of
the LCD Digital Operator.
Mode
4