Revision code
Date
3
April 1997
3A
April 1998
03B
March 2004
03C
December 2004
03D
August 2006
Revised content
Page 1--7: Added text to Menu display.
Page 2--7: Deleted the Specifications of 0 to 20mA on the table of
"Control output".
Page 3--4: Added "1 second min." to the display flowchart.
Page 3--6: Added text to Control period.
Changed "control period" to "control period (heat) " in
"Setting Example".
Added "1 second min." to the display flowchart.
Changed "control period" to "control period (heat)" in step
(8).
Page 3--9: Added "1 second min." to the display flowchart.
Page 3--11: Changed "(--5.0 to 105.0%)" to "(Standard:--5.0 to
105.0%, Heating and Cooling:--105.0 to 105.0%)" in
Manipulated variable at stop.
Added "1 second min." to the display flowchart.
Page 3--12: Deleted the display of "Changing the set point".
Added a display and some texts to Manual operation.
Page 3--13: Added a display to 40%AT.
Page 3--14: Added a display to 100%AT.
Added "1 second min." to the display flowchart.
Page 4--2: Moved the title of Heating and cooling control".
Added some texts to "Heating and cooling control".
Page 4--4: Modified the lower figure for "MV limiter".
Page 4--7: Moved "Run/Stop, Auto/Manual, Reference" to page
4--8.
Moved "Multi--SP" on page 4--8 to 4--7.
Page 4--8: Moved "Run/Stop, Auto/Manual, Reference" on page
4--7 to 4--8.
Moved "Multi--SP" on page 4--7.
Added "Factory setting is Set point" to Transfer output.
Added the title of "Transfer output scaling".
Page 4--10: Deleted (4) in Determining the LBA detection time.
Page 4--15: Modified display flowchart.
Page 4--17: Added "Conditions of Use" to MV at stop.
Page 5--27: Deleted "resetting the parameters" in the sixth lines from
the top.
Page 5--29: Added "Usually use the default value." to α.
Page 5--30: Added "Usually use the default value." to AT calculated
gain.
Added a figure to "Standby sequence reset method".
Page 5--31: Added "Usually use the default value." to AT hysteresis.
Page 5--35: Added some texts to the table.
Deleted "When you have selected the "manipulated vari-
able (heat)" parameter, the transfer output lower limit
during heating and cooling control becomes "0.0"".
Page 6--11: Deleted "End code12".
Page 7--5: Added "(auxiliary output 1)" to Input errors and A/D con-
verter error.
Page A--4: Modified the table of "Output Unit Ratings and Character-
istics".
Page A--5: Modified the diagram.
Page A--6: Added Remarks to the Parameter of "Remote/Local".
Page A--7: Changed the description "--5.0 to 105.0%" of "O" in
Transfer Output Type to "Standard:--50. To 105.0%,
Heating and cooling:0.0 to 105.0%.
Deleted two lines of the texts from the bottom.
Page A--10: Deleted 2) of "At the time the E5CK starts operation" in
"Startup Conditions of SRT".
Deleted 2) of "At the time set point is changed".
Page A--11: Deleted "Imposition Completion Condition of Step Con-
trol Amount".
Modified figure in "PID Constant Refreshing Conditions".
Page A--13: Changed "Type Name" and "Specification" in "Base unit".
Page A--14: Added some texts to "Format".
Modified the diagram in "Command".
Modified "X FORMAT HEAD LIST".
Added "Note".
Page 3--5: Added a sentence to "Output assignments".
Page A--7: Changed "OR--R/OR--D" to "OR--D/OR--R" in the middle
of the page.
Page 5--3: Changed the bottom table.
Page A--6: Add "FS" to the "Unit" column in three cells toward the
bottom of the table.
Page A-3:
Added information to table and accompanying notes.
Page 5-8:
Changed description of key operation in second bulleted
item.