CHAPTER 6 USING THE COMMUNICATIONS FUNCTION
Parameter No.
57
Input type
59
Scaling upper limit
58
Scaling lower limit
60
Decimal point
30
_C/_F selection
61
Control output 1 assignment
62
Control output 2 assignment
63
Auxiliary output 1 assignment
65
Alarm 1 type
66
Alarm 1 open in alarm
67
Alarm 2 type
68
Alarm 2 open in alarm
69
Alarm 3 type
70
Alarm 3 open in alarm
71
Direct/Reverse operation
28
Set point upper limit
27
Set point lower limit
72
PID / ON/OFF
73
ST
34
ST stable range width
35
α
85
AT calculated gain
37
Standby sequence reset method
36
Automatic return of display mode
93
AT hysteresis
55
LBA detection width
*1 See page 5-22.
*2 0: Control output (heat), 1: Control output (cool), 2: Alarm 1, 3: Alarm 2, 4: Alarm 3, 6: LBA.
*3 2: Alarm 1, 3: Alarm 2, 4: Alarm 3, 6: LBA, 7: Error 1, 8: Error 2
*4 See page 5-25.
*5 During temperature input, the range becomes the range of use of the selected sensor.
*6 See page 5-30.
Reading the status
6--8
Parameter
*5
*5
To read the E5CK controller status, use the X format "RX" command. For details,
see the Appendix: X Format Head List (page A-13).
Data Setting Range
0 to 21
Scaling lower limit +1 to 9999
--1999 to scaling upper limit --1
0 to 3
0 : _C, 1 : _F
0 to 4, 6
0 to 4, 6
2 to 4, 6 to 8
1 to 11
0: closed in alarm, 1: open in alarm
1 to 11
0: closed in alarm, 1: open in alarm
1 to 11
0: closed in alarm, 1: open in alarm
0: Reverse operation, 1: Direct operation
Set point lower limit +1 to scaling upper limit
Scaling lower limit to Set point upper limit --1
0: Advanced PID, 1: ON/OFF
0 : OFF, 1 : ON
0.1 to 999.9
0.00 to 1.00
0.1 to 10.0
0, 1
0 to 99
0.1 to 9.9
0.0 to 999.9
Mode
*1
*2
*2
*3
Setup
Setup
*4
*4
*4
Expansion
Expansion
*6