Misfeed Clearing Procedures Copier - Minolta EP4000 Operator's Manual

Hide thumbs Also See for EP4000:
Table of Contents

Advertisement

Misfeed Clearing Procedures
Copier
NOTE
Be careful not to touch the areas
marked with
with bare hands.
Caution
Swing down the Front Door and
1
remove the Exit Tray.
Open the Left Door. Pushing and, at
2
the same time, turning Misfeed
Removal Knob M1 , pull out the sheet
of paper.
CAUTION
The Fusing Unit and its surrounding areas
may be extremely hot. DO NOT touch any
part except the paper.
Close the Left Door and fit the Exit
3
Tray back into position.
4. When the Message "A paper misfeed has been detected." Appears
and
High Voltage
1136O035AA
1136O036AA
Swing Transport Section Release
4
Lever M2 down.
Turning Misfeed Removal Knob M3 ,
5
pull out the sheet of paper.
Swing Transport Section Release
6
Lever M2 back to its original
position. Close the Front Door.
115
1136O037AA
1136O038AA
1136O039AA

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ep5000

Table of Contents