Editing a Tone

PCM Drum Kit (PCMD)

PARTIAL 88
PARTIAL 1
WAVE
TVF
PITCH
TVF
ENV
ENV
Tab
Explanation
COMMON
Settings that apply to the entire tone.
Settings for the waveform that is the basis of the
WAVE
tone.
WMT
Make settings for velocity-switching between tones..
(Wave Mix Table)
PITCH
Settings related to pitch.
PITCH ENV
Settings for the pitch envelope.
TVF
Settings related to the filter.
TVF ENV
Settings for the TVF envelope.
TVA
Settings related to volume.
TVA ENV
Settings for the TVA envelope.
OUTPUT
Settings related to output.
Settings for the Drum Comp + EQ Assign part
COMP
compressor.
Settings for the Drum Comp + EQ Assign part
EQ
equalizer.
MFX
Settings for the multi-effect.
MFX CTRL
Settings for controlling MFX via MIDI.
MEMO
• If a note-on message is received, the partial number you're
editing will change.
• You can't edit the sounds of the GM2 bank or the ExPCM bank.
40
MFX
TVA
TVA
ENV
COMP+EQ 1
COMP+EQ 4
COMP+EQ 2
COMP+EQ 5
COMP+EQ 3
COMP+EQ 6

Saving a Tone/Drum Kit

Edits you make to a Tone/Drum Kit are temporary; they will be lost
when you turn off the unit or select another Tone/Drum Kit. If you
want to keep an edited Tone/Drum Kit, you must save it.
NOTE
When you execute the Write operation, the existing data at the
write destination will be overwritten.
1.
In the TONE EDIT screen, hold down the [SHIFT] button
and press the [EDIT] button.
2.
Assign a name to the tone/drum kit.
For details on assigning a name, refer to "Assigning a Name"
(p. 29).
3.
Press the [ENTER] button.
4.
Move the cursor to the save destination, and use the
value dial or the [DEC] [INC] buttons to specify the save
destination.
5.
Press the [ENTER] button.
A message will ask "Are you sure?"
6.
To execute, select "OK" and press the [ENTER] button.
MEMO
If you decide to cancel without saving, press the [EXIT] button.
NOTE
Never turn off the unit while data is being written to memory.