OmniSwitch 6450 Chassis and Hardware Components
10/100/1000 Mbps Power over Ethernet Port – RJ-45 Pinout
Pin Number
1
2
3
4
5
6
7
8
Overtemp Condition
The OmniSwitch is designed to operate within a specified operating temperature as noted under the
specifications section. However, in the event that the normal operating temperature of the switch is
exceeded, the following will occur:
•
Upon crossing the configured Upper Threshold, a trap will be sent. (See the OmniSwitch 6250/6450
Network Configuration Guide for information on configuring switch thresholds.)
If the temperature continues to rise and reaches the Danger Threshold, the following will occur:
•
OK LED will display solid Amber.
•
The switch will automatically shutdown
•
Once the temperature drops to an acceptable operating level, the switch will automatically restart.
Check the following if an overtemp condition exists:
•
Verify that the switch is installed properly in an environment that adheres to the installation
instructions in the following chapters.
•
Verify proper airflow to the chassis.
•
Time of the failure
Use the
snmp station
configuring an SNMP station.
OmniSwitch 6450 Hardware Users Guide
Description
RX+ (-VDC)
RX- (-VDC)
TX+ (+VDC)
TX- (+VDC)
command and refer to the SNMP Configuration chapter for information on
July 2012
Overtemp Condition
page 2-31