Overtemp Condition
10/100/1000 Mbps Power over Ethernet Port – RJ-45 Pinout
Pin Number
1
2
3
4
5
6
7
8
Overtemp Condition
The OmniSwitch 6855 is designed to operate within a wider operating temperature range than normal
network equipment as noted under the specifications section. However, in the event that the normal operat-
ing temperature of the switch is exceeded, the following will occur:
Upon crossing the configured overtemperature threshold, a trap will be sent. (See the OmniSwitch AOS
•
Release 6 Network Configuration Guide) for information on configuring switch thresholds.
If the temperature continues to rise above the maximum operating temperature, the following will occur:
OK LED will display solid Amber.
•
The switch will automatically shutdown
•
Once the temperature drops to an acceptable operating level, the switch will automatically restart.
•
Check the following if an overtemp condition exists:
Verify that the switch is installed properly in an environment that adheres to the installation instruc-
•
tions in the following chapters.
Verify proper airflow to the chassis.
•
page 2-42
Description
RX+ (-VDC)
RX- (-VDC)
TX+ (+VDC)
TX- (+VDC)
OmniSwitch 6855 Series Hardware Users Guide
OmniSwitch 6855 Series Chassis and Hardware Components
March 2009