OmniSwitch 6350 Chassis and Hardware Components
10/100/1000 Mbps Power over Ethernet Port – RJ-45 Pinout
Pin Number
1
2
3
4
5
6
7
8

Overtemp Condition

The OmniSwitch is designed to operate within a specified operating temperature as noted under the
specifications section. However, in the event that the normal operating temperature of the switch is
exceeded, the following will occur:
Upon crossing the configured Upper Threshold, a trap will be sent. (See the OmniSwitch 6250/6350/
6450 Network Configuration Guide for information on configuring switch thresholds.)
If the temperature continues to rise and reaches the Danger Threshold, the following will occur:
OK1 LED will display solid Amber.
The switch will automatically shutdown
Once the temperature drops to an acceptable operating level, the switch will automatically restart.
Check the following if an overtemp condition exists:
Verify that the switch is installed properly in an environment that adheres to the installation
instructions in the following chapters.
Verify proper airflow to the chassis.
Time of the failure
Use the
snmp station
configuring an SNMP station.
OmniSwitch 6350 Hardware Users Guide
Description
RX+ (-VDC)
RX- (-VDC)
TX+ (+VDC)
TX- (+VDC)
command and refer to the SNMP Configuration chapter for information on
September 2015
Overtemp Condition