10/100/1000 Mbps Power over Ethernet Port – RJ-45 Pinout
Pin Number
1
2
3
4
5
6
7
8
Overtemp Condition
The OmniSwitch is designed to operate within a specified operating temperature as noted under the speci-
fications section. However, in the event that the normal operating temperature of the switch is exceeded,
the following will occur:
•
Upon crossing the configured Upper Threshold, a trap will be sent. (See the Network Configuration
Guide for information on configuring switch thresholds).
If the temperature continues to rise and reaches the Danger Threshold, the following will occur:
•
OK LED will display solid Amber.
•
The switch will automatically shutdown
•
Once the temperature drops to an acceptable operating level, the switch will automatically restart.
Check the following if an overtemp condition exists:
•
Verify that the switch is installed properly in an environment that adheres to the installation instruc-
tions in the following chapters.
•
Verify proper airflow to the chassis.
•
Time of the failure
Use the
snmp station
uring an SNMP station.
OmniSwitch 6450 Series Hardware Users Guide
Description
RX+ (-VDC)
RX- (-VDC)
TX+ (+VDC)
TX- (+VDC)
command and refer to the SNMP Configuration chapter for information on config-
November 2011
page 2-17