SYSTEM WIRING DETAILS
PIN-1 YELLOW Starter Output-This wire will test 0V when the key is off, in the Accessory position and when
the Ignition is in the on position. The starter wire is 12volts during the start/ crank position only.
PIN-2 GREEN
Heater/Acc Output-This wire will test 0V when key is off, 12volts in the ACC and iIGN
positions and off during start/ crank position.
PIN-3 RED
12volt Input(30amp)- This input supplies the 12volt power for the Ignition, Park Lights and
the Selectable outputs.
PIN-4 RED
12volt Input(30amp)- This input supplies the 12volt power for the Accessory and Starter
outputs.
PIN-5 BLUE
Ignition Output- This wire will test 0V in the off and Accessory positions the switch to12volts
in the Ignition and Start positions.
PIN-6 WHITE
Selectable Output - 2nd Ignition, Accessory or Start output. Programmable. (See Page 21).
Note: This output does not switch to default when the system is reset.
PIN-1 BROWN
(+) Siren / (-) Horn (Programmable)- Connect this wire to the Brown or Red wire on the
SIREN (Alarm Models) This output can be programmed to act as an additional HORN output (+)
PIN-2 ORANGE
Starter Kill/ Anti-Grind- This wire can be connected to an additional relay to disable the
start circuit when the lock button is pressed. The output will also stay on when remote started, this will prevent
the starter motor from being re-engaged while the vehicle is running.
PIN-3 WHITE
Jumper Selectable Park Light Output (+ or -)- Connect to the vehicles positive park light
wire or change the jumper and connect to the vehicle negative park light wire. The default position of the jumper
is Positive Park light Output.
PIN-4 BLACK
System Ground Input- Connect to chassis ground.
PIN 1- GREEN Wire- Negative Lock Output
Connect to lock wire from the switch on vehicles with a negative type switch. **LOW CURRENT ONLY**
PIN 2- 12volt Output for Door Lock Module
This output will supply 12volts for a plug-in type door lock module. Do not use this input to power-up relays
**LOW CURRENT ONLY**
PIN 3- BLUE Wire- Negative Unlock Output
Connect to lock wire from the switch on vehicles with a negative type switch. **LOW CURRENT ONLY**