HP Integrity cx2600 Maintenance Manual page 70

Hp integrity cx2600 operations and maintenance guide
Hide thumbs Also See for Integrity cx2600:
Table of Contents

Advertisement

Table 4-8 Interpret Diagnostic and System LEDs
Diag 1 LED
Off
6.
Power off the server and disconnect power. (If the system has shut itself down, only
disconnect power.) To power off the server and disconnect power at the cabinet or facility
power disconnect device, press the front panel Power button.
7.
Install the MP card.
8.
To apply power, press the front panel Power button. Observe the power LED, the diagnostic
LEDs, and the system LED. Also, observe the LEDs on the MP card.
If the fault LED on the power supply is lit, replace the MP card.
If the front panel power LED is not lit, replace the MP card.
If the MP fault LED (DS1) is lit, replace the MP card or the system board.
If the MP heartbeat LED (DS2) is not flashing, replace the MP card or the system board.
For additional information, see the SEL. The log indicates that no DIMMs are installed.
To interpret the diagnostic and system LEDs, use
Table 4-9 Interpret Diagnostic and System LEDs
Diag 1 LED
Off
9.
Power off the server and disconnect power. (If the system has shut itself down, only
disconnect power.) To power off the server and disconnect power at the cabinet or facility
power disconnect device, press the front panel Power button.
10. Install a CPU and power module in the CPU 0 position.
11. To apply power to the server, press the front panel Power button. Observe the power LED,
the diagnostic LEDs, and the system LED.
If the fault LED on the power supply is lit, replace the processor power module, the
processor, or both.
If the front panel power LED is not lit, replace the processor power module, the
processor, or both.
For additional information, see the SEL.
To interpret the diagnostic and system LEDs, use
Table 4-10 Interpret Diagnostic and System LEDs
Diag 1 LED
Green
70
Troubleshooting
Diag 2 LED
Diag 3 LED
Red
Off
Any Other LED Status Display
Diag 2 LED
Diag 3 LED
Red
Off
Any Other LED Status Display
Diag 2 LED
Diag 3 LED
Green
Green
Diag 4 LED
System LED
Off
Flashing Red
Table
Diag 4 LED
System LED
Off
Flashing Red
Table
Diag 4 LED
System LED
Green
Green or Red
When stable
Description
The BMC is reporting a level 7 error
due to the missing server component.
Continue with the build up
procedure.
Replace the system board. For
additional information, see
(page
58).
4-9.
Description
The BMC is reporting a fatal error due
to missing DIMMs. Continue with the
build up procedure.
Replace the MP card or the system
board. For additional information, see
Table 4-3 (page
58).
4-10.
Description
Boot in progress.
Table 4-3