HP Integrity cx2600 Maintenance Manual page 63

Hp integrity cx2600 operations and maintenance guide
Hide thumbs Also See for Integrity cx2600:
Table of Contents

Advertisement

Table 4-5 EFI Error and Warning Messages (continued)
Error Number
19
Error writing BMC token on download
20
Non-volatile Memory (NVM) token access error
21
BMC token write error during NVM write
through
22
Error reading BMC token on upload to NVM
23
Error reading BMC first boot token
24
Primary field interoperability testing (FIT) failed
25
Secondary FIT failed
26
Processor abstraction layer (PAL) A warning;
One copy of PAL is bad
27
PAL A warning; PAL is not compatible with at
least 1 CPU
28
Memory errors detected and Page Deallocation
Table (PDT) is disabled
30
Memory required reinterleave to get a good
page 0
31
One or more ranks have chipspare disabled
33
One or more memory ranks are mismatched or
deallocated
34
Memory deallocated because of a loading error
35
Memory load order error
36
The PDT is full
37
At least one CPU has bad fixed core ratio
38
All CPUs were slated for compatibility
deconfiguration
39
Incompatible CPUs detected
40
CPUs installed with mixed cache sizes
41
CPUs installed with mixed steppings
42
All CPUs are overclocked
Message
Description/Solution
Communication with the BMC failed. Replace the
system board.
Communication with the BMC failed. Replace the
system board.
Communication with the BMC failed. Replace the
system board.
Communication with the BMC failed. Replace the
system board.
Communication with the BMC failed. Replace the
system board.
Reflash firmware.
Reflash firmware.
Reflash firmware.
Update firmware.
Reseat DIMMs; if error persists replace bad
DIMMs.
Information only, no action required.
Information only, no action required.
Check memory installation. Match DIMM part
numbers within each quad.
Check memory installation. DIMMs must be
installed with smallest capacity in the first quad,
an equal or larger capacity in the second quad, and
an equal or larger capacity in the third quad.
Check memory installation. DIMMs must be
installed with smallest capacity in the first quad,
an equal or larger capacity in the second quad, and
an equal or largest capacity in the third quad.
Clear with pdt clear command in the EFI Shell.
Check processor installation. Verify installation
and that identical processors have been installed.
Processor failure. Verify installation and replace
processor. Contact the HP Support Center for
assistance.
Check processor installation and match CPU part
numbers. CPUs must be identical.
Check processor installation. Match CPU part
numbers. CPUs must be identical. This always
causes a stopboot.
Check processor installation and match CPU part
numbers. CPUs must be identical.
Check processor installation and match CPU part
numbers. CPUs must be identical.
Error Messages
63