HP Integrity cx2600 Maintenance Manual page 121

Hp integrity cx2600 operations and maintenance guide
Hide thumbs Also See for Integrity cx2600:
Table of Contents

Advertisement

2.
When the power supply is fully inserted into the server chassis, tighten the two mounting
screws to secure the power supply in place.
3.
Press up on the two lower tabs on the terminal barrier strip cover to snap off the cover.
WARNING!
Always check that the power cable is not connected to a power source before
attempting to connect the power cable to the power supply terminals. Failure to heed this
warning can result in injury.
4.
Connect the power cable leads to the power supply terminals
Figure 7-6 Power Supply Terminals
rearview
5.
Reinstall the terminal barrier strip cover. Hang the cover on the upper tabs and snap the
cover into place.
6.
Route the power cable through the power supply cable clamp and tighten the two knurled
knobs to secure the cable in place.
7.
Connect the power cable to the DC power source.
Fault
DC Out
DC In
dc Power
dc Power
Supply Wire
Supply Wire
Removing and Replacing Hot-Swappable Power Supplies
(Figure
7-6).
Fault
DC Out
DC In
dc Power
Supply Wire
Supply Wire
dc Power
121