Therefore, if you execute the rmon statistics 5 command, you can use etherStatsOctets.5 to replace the
parameter.
This example enables the RMON agent to do the following:
Samples and monitors interface GigabitEthernet 1/0/1.
Obtains the incoming-packet count in its absolute value. If the total number of incoming bytes
reaches 5000, the system logs the event. If the total number of incoming bytes is no more than 5,
the system takes no action. To view the event log, use the display rmon eventlog command.

rmon event

Syntax
rmon event entry-number [ description string ] { log | log-trap log-trapcommunity | none | trap
trap-community } [ owner text ]
undo rmon event entry-number
View
System view
Default level
2: System level
Parameters
entry-number: Specifies the event entry index, which ranges from 1 to 65535.
description string: Specifies the event description, a string of 1 to 127 characters.
log: Logs the event when it occurs.
log-trap log-trapcommunity: Specifies the log and trap events. The system performs both logging and
trap sending when the event occurs. log-trapcommunity indicates the community name of the network
management station that receives trap messages, a string of 1 to 127 characters.
none: Performs no action when the event occurs.
trap trap-community: Specifies the trap event. The system sends a trap with a community name when the
event occurs. trap-community specifies the community name of the network management station that
receives trap messages, a string of 1 to 127 characters.
owner text: Specifies the entry owner, a case-sensitive string of 1 to 127 characters that can contain
spaces.
Description
Use rmon event to create an entry in the RMON event table.
Use undo rmon event to remove a specified entry from the RMON event table.
When creating an event entry, you can define the actions that the system takes when the event is
triggered by its associated alarm in the alarm table. The system can log the event, send a trap, do both,
or do neither based on your configuration.
An entry cannot be created if the values of the specified event description (description string), event type
(log, trap, logtrap or none), and community name (trap-community or log-trapcommunity) to be identical
to those of the existing event entry in the system.
Up to 60 event entries can be created.