This example shows that event 1 generated two logs.

display rmon history

Syntax
display rmon history [ interface-type interface-number ] [ | { begin | exclude | include }
regular-expression ]
View
Any view
Default level
1: Monitor level
Parameters
interface-type interface-number: Specifies an interface by its type and number.
|: Filters command output by specifying a regular expression. For more information about regular
expressions, see Fundamentals Configuration Guide.
begin: Displays the first line that matches the specified regular expression and all lines that follow.
exclude: Displays all lines that do not match the specified regular expression.
include: Displays all lines that match the specified regular expression.
regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Description
Use display rmon history to display RMON history control entry and history sampling information.
After you have created the history control entry on an interface, the system calculates the information of
the interface periodically and saves the information to the etherHistoryEntry table. You can use this
command to display the entries in this table.
To configure the number of history sampling records that can be displayed and the history sampling
interval, use the rmon history command.
Related commands: rmon history.
Examples
# Display RMON history control entry and history sampling information for interface GigabitEthernet
1/0/1.
<Sysname> display rmon history gigabitethernet 1/0/1
HistoryControlEntry 1 owned by null is VALID
Samples interface
Sampling interval
Sampled values of record 1 :
dropevents
packets
multicast packets : 6
undersize packets : 0
fragments
collisions
: GigabitEthernet1/0/1<ifIndex.1>
: 10(sec) with 5 buckets max
: 0
, octets
: 43
, broadcast packets
, CRC alignment errors : 0
, oversize packets
: 0
, jabbers
: 0
, utilization
90
: 3166
: 3
: 0
: 0
: 0