Notes on connecting/disconnecting cables

V
CAUTION!
Always read the documentation supplied with the device you wish to
connect.
Never connect, or disconnect cables during a thunderstorm.
Never pull on a cable when disconnecting it. Always take hold of the
cable by the plug.
Follow the sequence described below to connect or disconnect external
devices to or from the server:
Be sure to wait for 10 seconds or more after shutdown before turning the
server on.
Connecting cables
Ê Turn off all power and equipment switches.
Ê Disconnect all power plugs from the properly grounded power outlets.
Ê Connect all cables to the server and peripherals.
Ê Plug all data communication cables into the utility sockets.
Ê Plug all power cords into the properly grounded power outlets.
Disconnecting cables
Ê Turn off all power and equipment switches.
Ê Disconnect all power plugs from the properly grounded power outlets.
Ê Unplug all data communication cables from the utility sockets.
Ê Disconnect the relevant cables from the server and all the peripherals.
I
For connecting or disconnecting LAN cables, the server needs not to be
powered off. To avoid loss of data teaming/bonding function has to be
enabled.
RX600 S6
Operating Manual
Hardware installation
55