Identifying The Defective Memory - Fujitsu PRIMERGY RX600 S6 Operating Manual

Fujitsu server user manual
Hide thumbs Also See for PRIMERGY RX600 S6:
Table of Contents

Advertisement

CSS components
8.1.5.1

Identifying the defective memory

The faulty memory module can be identified from the corresponding DIMM Fault
LED on the respective memory board (see
Ê Open the server (see
Figure 28: Button and indicators on memory board
1
ATTN button
2
ATTN LED (orange)
3
Power LED (green)
Ê Use the DIMM Fault LEDs (5) to identify the faulty memory module.
The respective DIMM Fault LED lights up orange and indicates the slot on
the memory board that is occupied by the faulty memory module.
Ê Make a note of which LED (e.g. "1B") on which memory board is lit orange.
Ê Press the ATTN button (1) .
Ê Wait until ATTN LED (2) and Power LED (3) are turned off.
Ê Remove the memory board as described in
in question" on page 111
110
"Opening the server" on page
4
5
Operating Manual
figure
28) when the server is open.
125).
Mirror LED (green)
8x DIMM Fault LED (orange)
"Removing the memory board
RX600 S6