Indicators On The Accessible Drives/Components; Serverview Local Service; Optical Drive Activity Indicator - Fujitsu PRIMERGY RX600 S6 Operating Manual

Fujitsu server user manual
Hide thumbs Also See for PRIMERGY RX600 S6:
Table of Contents

Advertisement

Global Error indicator (orange)
– Lights up orange if a prefailure event has been detected that
requires (precautionary) service intervention.
– Flashes orange if an error was detected that requires service
intervention.
– Does not light up if there is no critical event.
If the event is still acute after a power failure, the indicator is
activated after the restart.
The indicator also lights up in standby mode.
You can find more details on the indicated errors in the System
Event Log (SEL), on the ServerView Local Service Display, in the
ServerView Operations Manager or via the iRMC S2's Web
interface.
5.1.1.3

Indicators on the accessible drives/components

Optical drive activity indicator

Lights up green when the storage medium is being accessed.
ServerView Local Service Display
You can use the slot mechanism to pull out the ServerView Local Service
Display from the server housing and read the information. Press the front of the
module to release the lock.
You can also pivot the ServerView Local Service Display down by an angle of
120° from its normal position. This makes reading easier when the server is
located very high in the rack.
Further information on using the ServerView Local Service Display is provided
in the "Customer Self Service (CSS)" manual.
RX600 S6
Operating Manual
Starting up and operation
61