AT Command Set

3.25 AT+FTM Transmit Data

Test command
Response
AT+FTM=?
(List of supported modulation modes) OK
Parameter
See write command
Write command
This command causes the TA to transmit data using the modulation mode de-
fined below. An ERROR response code results if this command is issued while
AT+FTM=<mod>
the modem is on-hook.
Response
CONNECT
If error is related to ME functionality:
ERROR
Parameter
<mod>
Reference
Note
TIA/EIA-578
Used for Fax class 1 only

3.26 AT+FTS Stop Transmission and Wait

Write command
This command causes the TA to terminate a transmission and wait for <time> 10
millisecond intervals before responding with the OK result code to the DTE.
AT+FTS=<time>
Response
An ERROR response code results if this command is issued while the modem is
on-hook.
Parameter
<time>
Reference
Note
TIA/EIA-578
Used for Fax class 1 only
MC35_ATC_01_V05.00
modulation mode
96
V.29
9600 bps
72
V.29
7200 bps
48
V.27ter
4800 bps
24
V.27ter
2400 bps
0 – 85
no. of 10 millisecond intervals