Technical data

Because you insert the SIMATIC IOT2000 SG-Shield into the SIMATIC IOT2050, the same
technical specifications apply as for SIMATIC IOT2050:
• Type of protection: IP20 in accordance with IEC 60529;
• Electromagnetic compatibility;
• Ambient conditions
All technical specifications can be found in the SIMATIC IOT2050 Operating Instructions
support.industry.siemens.com/cs/de/en/view/109779016) in the section "Technical
specifications".
Rated conditions
Ambient temperature
Load cell interface
Accuracy
Input signal resolution
Measuring range
Supply of the full bridge
Connection
Strain gauge input resistance
Electrical isolation
SIMATIC IOT2000 SG-Shield
Operating Instructions, 08/2021, A5E50985404-AA
0 ... 55 °C
0.05%
± 1 000 000
± 4 mV/V
4.85 V DC +2/-3%
4-wire or 6-wire
50 ... 4100 Ω
500 V AC
9
(https://
29