Siemens MC35 Command Set page 99

Module/terminal
Hide thumbs Also See for MC35:
Table of Contents

Advertisement

AT Command Set
<value>
Reference
Note
GSM 07.07
· Only the indicators which are registered (see AT+CIND command), will be re-
ported if CMER is enabled.
· After CMER has been switched on, +CIEV URCs for all registered indicators
with their default value will be presented to the TE.
· While the ME is in online data mode, no URC will be displayed. Each +CIEV
URC is replaced with a Break (100 ms), and is stored in a buffer. Once the ME
goes into command mode (after +++ was entered), all URCs stored in the
buffer will be output.
Exception: For "message" indicator, please note that each incoming short mes-
sage will cause a Break.
· See AT+CIND in Chapter 4.19.
MC35_ATC_01_V05.00
"signal"
Signal quality (0-7 or 99 if not measurable). The
indicated value is the bit error rate of the signal
received. See also Chapter 4.46.
"service"
Service availability (0-1).
"sounder"
Sounder activity (0-1). The indicator provides in-
formation about tones generated in the ME. The
value 1 means for example:
Incoming call - ME is ringing.
Waiting call – ME generates waiting call tone (if
call waiting is enabled).
Outgoing call – ME generates Call Progress tone.
Outgoing call – ME generates BUSY tone.
The value changes to 0, when the tone stops.
"message"
Unread short message(s) (0-1).
"call"
Call in progress (0-1). Voice und data calls only.
The indicator changes its value as soon as a call
has been established, for example when both in-
terlocutors are connected or when the call ends.
"roam"
Roaming indicator (0-1).
"smsfull"
A short message memory storage in the MT has
become full (1) or memory locations are available
(0); i.e. the range is (0-1).
integer type value, in the range stated above for the corresponding
<descr>.
Page 99 of 256