Table PD-54— Belt Drive Evaporator Fan Performance — 10-Ton — THC120A3,A4,AW —Horizontal Airflow
.10
.20
CFM
RPM
BHP
RPM
BHP
3200
3600
746
1.18
777
1.27
4000
822
1.59
850
1.70
4400
898
2.09
925
2.21
4800
974
2.69
1000
2.83
For Standard Evaporator Fan Speed (RPM), reference Table PD-50.
NOTES:
NOTES:
NOTES:
NOTES:
NOTES:
Data includes pressure drop due to standard filters and wet coils.
No accessories or options are included in pressure drop data.
Refer to Table PD-54 to determine additional static pressure drop due to other options/accessories
3-HP Fan Motor Heat (MBH) = 2.900 x Fan BHP+.475.
5-HP Fan Motor Heat (MBH) = 2.950 x Fan BHP+.470.
1. Field Supplied Motor Sheave 1VM50 x 7/8 inch, Fan Sheave AK89,
and Belt AX40 required
Table PD-54 — Continued
1.10
1.20
CFM
RPM
BHP
RPM
BHP
3-HP Standard Motor & Drive
3200
1044
2.28
1072
2.42
3600
1093
2.74
1124
2.92
4000
1135
3.21
1167
3.42
4400
1177
3.73
1207
3.96
4800
1229
4.39
1254
4.59
5-HP Oversized Motor & Drive
Table PD-55— Belt Drive Evaporator Fan Performance — 10-Ton — THC120A3,A4,AW —Horizontal Airflow — Dehumidification (Hot Gas Reheat)
.10
.20
CFM
RPM
BHP
RPM
BHP
2000
2400
578
0.48
2800
596
0.58
640
0.67
3200
671
0.85
706
0.93
***MINIMUM AIR VOLUME REQUIRED FOR USE WITH OPTIONAL ELECTRIC HEAT IS 3200 CFM.
***MINIMUM AIR VOLUME REQUIRED FOR USE WITH OPTIONAL ELECTRIC HEAT IS 3200 CFM.
***MINIMUM AIR VOLUME REQUIRED FOR USE WITH OPTIONAL ELECTRIC HEAT IS 3200 CFM.
***MINIMUM AIR VOLUME REQUIRED FOR USE WITH OPTIONAL ELECTRIC HEAT IS 3200 CFM.
***MINIMUM AIR VOLUME REQUIRED FOR USE WITH OPTIONAL ELECTRIC HEAT IS 3200 CFM.
NOTES:
NOTES:
NOTES:
NOTES:
NOTES:
Data includes pressure drop due to standard filters and wet coils.
Data does not include pressure drop due to reheat coil.
3-HP Fan Motor Heat (MBH) = 2.900 x Fan BHP+.475.
1. BAYLSDR010A Required.
2. BAYLSDR010A Required.
Table PD-55 — Continued
1.10
1.20
CFM
RPM
BHP
RPM
BHP
3-HP Standard Motor & Low
Static Drive Accessory Kit (2)
2000
877
1.15
906
1.24
2400
931
1.47
958
1.58
2800
989
1.84
1015
1.97
3200
1044
2.28
1072
2.42
44
Performance
Data
External Static Pressure (Inches of Water)
.30
.40
RPM
BHP
RPM
BHP
3-HP Standard Motor & Field Supplied
Low Static Drive (1)
748
1.06
787
1.19
811
1.39
849
1.54
879
1.81
912
1.95
950
2.32
977
2.46
1023
2.95
1046
3.07
External Static Pressure (Inches of Water)
1.30
1.40
RPM
BHP
RPM
BHP
1097
2.57
1122
2.71
1151
3.09
1176
3.25
1198
3.63
1227
3.84
1239
4.19
1268
4.42
1282
4.83
1310
5.07
External Static Pressure (Inches of Water)
.30
.40
RPM
BHP
RPM
BHP
3-HP Standard Motor & Low
Static Drive Accessory Kit (1)
584
0.43
639
0.53
627
0.57
683
0.70
686
0.79
728
0.90
748
1.06
787
1.19
External Static Pressure (Inches of Water)
1.30
1.40
RPM
BHP
RPM
BHP
933
1.33
961
1.43
983
1.68
1008
1.78
1040
2.09
1064
2.21
1097
2.57
1122
2.71
.50
.60
RPM
BHP
RPM
BHP
RPM
824
1.32
864
1.47
906
883
1.68
916
1.82
950
946
2.12
977
2.28
1006
1008
2.63
1039
2.81
1067
1072
3.23
1101
3.42
1130
Trane's factory supplied motors, in commercial equipment, are definite purpose
motors, specifically designed and tested to operate reliably and continuously at
all cataloged conditions. Using the full horsepower range of our fan motors as
shown in our tabular data will not result in nuisance tripping or premature motor
failure. Our product's warranty will not be affected.
1.50
1.60
RPM
BHP
RPM
BHP
RPM
1145
2.84
1168
2.99
1189
1201
3.42
1224
3.58
1246
1254
4.05
1278
4.23
1301
1297
4.67
1324
4.90
1351
1338
5.32
1365
5.58
.50
.60
RPM
BHP
RPM
BHP
RPM
3-HP Standard Motor & Low
Static Drive Accessory Kit (2)
682
0.62
721
0.71
755
734
0.83
776
0.94
812
776
1.04
822
1.19
865
824
1.32
864
1.47
906
1.50
1.60
RPM
BHP
RPM
BHP
RPM
3-HP Standard Motor & Drive
988
1.54
1014
1.64
1038
1032
1.89
1056
2.00
1080
1087
2.34
1110
2.46
1132
1145
2.84
1168
2.99
1189
(10 Ton)
High Efficiency
.70
.80
.90
BHP
RPM
BHP
RPM BHP
3-HP Standard Motor
& Drive
1.64
946
1.81
983
1.98
987
2.16
1024 2.35
2.43
1035
2.60
1067 2.79
2.98
1094
3.16
1121
3.62
1156
3.81
1181
5-HP Oversized Motor & Drive
1.70
1.80
1.90
BHP
RPM
BHP
RPM
3.12
1210
3.27
1231 3.41
3.74
1268
3.90
1289 4.06
4.41
1323
4.60
1344 4.77
5.12
1376
5.35
1398 5.56
.70
.80
.90
BHP
RPM
BHP
RPM
0.79
787
0.88
818
1.05
845
1.15
876
1.34
900
1.47
932
1.64
946
1.81
983
3-HP Oversized Motor & Drive
Trane's factory supplied motors, in commercial
equipment, are definite purpose motors, specifically
designed and tested to operate reliably and
continuously at all cataloged conditions. Using the full
horsepower range of our fan motors as shown in our
tabular data will not result in nuisance tripping or
premature motor failure. Our product's warranty will
not be affected.
1.70
1.80
1.90
BHP
RPM
BHP
RPM
1.74
1063
1.85
1087
2.11
1103
2.22
1126
2.58
1154
2.71
1176
3.12
1210
3.27
1.00
RPM BHP
1.97
1015
2.13
1060 2.55
1101
2.99
3.33
1147
3.52
4.00
1206 4.19
2.00
BHP
RPM
BHP
1250 3.54
1308 4.20
1365 4.95
1420 5.75
1.00
BHP
RPM
BHP
0.97
849
1.06
1.26
904
1.36
1.60
962
1.73
1.97
1015
2.13
2.00
BHP
RPM
BHP
1.96
1111
2.07
2.34
1149
2.46
2.83
1 196
2.95
RT -PRC005-EN

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents