Trane Precedent RT-PRC005 User Manual page 14

Packaged cooling with electric heat rooftop units 3 - 10 tons - 60 hz
Table of Contents

Advertisement

Table GD - 4— General Data
1
Cooling Performance
Gross Cooling Capacity
2
EER
Nominal CFM / ARI Rated CFM
ARI Net Cooling Capacity
Integrated Part Load Value (IPLV)
System Power (kW)
Compressor
No./Type
Outdoor Sound Rating (dB)
Outdoor Coil — Type
Tube Size (in.) O.D.
Face Area (sq ft)
Rows/FPI
Indoor Coil — Type
Tube Size (in.)
Face Area (sq ft)
Rows/FPI
Refrigerant Control
Drain Connection No./Size (in.)
Outdoor Fan — Type
No. Used/Diameter (in.)
Drive Type/No. Speeds
CFM
No. Motors/HP
Motor RPM
Belt Drive Indoor Fan — Type
No. Used
Diameter x Width (in.)
Drive Type/No. Speeds
No. Motors
Motor HP (Standard/Oversized)
Motor RPM (Standard/Oversized)
Motor Frame Size
9
Filters — Type Furnished
(No.) Size Recommended (in.)
Optional Hot Gas Reheat Coil — Type
Tube Size (in.) OD
Face Area (sq. ft.)
Rows/FPI
Refrigerant Charge (Lbs of R-22)
NOTES:
1. Cooling Performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is
net and includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Certified in accordance with the Unitary Air-Conditioner Equipment
certification program, which is based on ARI Standard 210/240.
2. SEER is rated at ARI conditions and in accordance with DOE test procedures.
3. Integrated Part Load Value is rated in accordance with ARI Standard 210/240 or 360. Units are rated at 80°F ambient, 80°F entering dry bulb, and 67°F entering wet bulb ar
ARI rated cfm.
4. Outdoor Sound Rating shown is tested in accordance with ARI Standard 270. For more information refer to Table PD-51.
5. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions.
6. EER shown is for downflow airflow. EER for horizontal airflow: THC072A - 11.3, THC092A and THC102A - 11.3, THC120A - 10.7.
7. System Power (kW) shown is for downflow airflow. System Power (kW) for horizontal airflow: THC072A - 6.2, THC092A - 7.88, THC102A - 8.58, THC120A - 10.09.
8. Integrated Part Load Value (IPLV) shown is for downflow airflow. IPLV for horizontal airflow: THC092A - 11.5, THC102A - 11.6, THC120A - 11.5.
9. Optional 2" Pleated Filters also available.
10. Net Cooling Capacity shown is for downflow airflow. Net Cooling for horizontal airflow: THC092A - 89,000, THC102A - 97,000, THC120A - 108,000.
14
General
Data
6 Ton
Convertible Units
THC072A3, A4, AW
73,000
6
11.5
2,400/2,100
70,000
3
6.09
7
1/Climatuff Scroll
4
89
Lanced
0.3125
17 .00
3/17
Lanced
0.3125
9.89
3/16
Short Orifice
1/¾ NPT
Propeller
1/26
Direct/1
6100
1/0.70
1075
FC Centrifugal
1
12 x 12
Belt/Variable Speed
1
1.00/2.00
1750
56
Throwaway
(4) 16 x 25 x 2
5
10.7
(6 - 10 Ton)
High Efficiency
7½ Ton
8½ Ton
Convertible Units
Convertible Units
THC092A3, A4, AW
THC102A3, A4. AW
94,000
6
11.5
3,000/2,625
3,400/3,000
10
90,000
8
11.9
7 .83
7
2/Climatuff Scrolls
2/Climatuff Scrolls
91
Lanced
0.3125
17 .50
3/17
Lanced
0.3125
12.36
3/16
Short Orifice
Short Orifice
1/¾ NPT
Propeller
Propeller
1/26
Direct/1
6200
1/0.70
1075
FC Centrifugal
FC Centrifugal
1
15 x 15
Belt/Variable Speed
Belt/Variable Speed
1
2.00/3.00
2.00/3.00
1750
56
Throwaway
Throwaway
(4) 20 x 25 x 2
(4) 20 x 25 x 2
6.4 Circuit 1
7 .4 Circuit 1
6.2 Circuit 2
7 .1Circuit 2
10 Ton
Convertible Units
THC120A3, A4, AW
103,000
117 ,000
6
6
11.5
11.2
4,000/3,200
10
10
98,000
109,000
8
8
12.1
12.0
8.52
7
9.73
7
2/Climatuff Scrolls
89
88
Lanced
Lanced
0.3125
0.3125
19.83
27 .21
3/17
3/17
Lanced
Lanced
0.3125
0.3125
12.36
12.36
4/16
5/16
Short Orifice
1/¾ NPT
1/¾ NPT
Propeller
1/26
1/26
Direct/1
Direct/1
6600
7000
1/0.75
1/0.75
1075
1075
FC Centrifugal
1
1
15 x 15
15 x 15
Belt/Variable Speed
1
1
3.00/5.00
1750
1750/3450
56
56
Throwaway
(4) 20 x 25 x 2
Lanced
0.375
5.19
2/16
11.0 Circuit 1
7 .3Circuit 2
RT -PRC005-EN