Table GD - 3 — General Data
Cooling Performance
1
Gross Cooling Capacity
2
SEER / EER
Nominal CFM / ARI Rated CFM
ARI Net Cooling Capacity
System Power (kW)
Compressor
No./Type
3
Outdoor Sound Rating (dB)
Outdoor Coil — Type
Tube Size (in.) O.D.
Face Area (sq ft)
Rows/FPI
Indoor Coil — Type
Tube Size (in.)
Face Area (sq ft)
Rows/FPI
Refrigerant Control
Drain Connection No./Size (in.)
Outdoor Fan — Type
No. Used/Diameter (in.)
Drive Type/No. Speeds
CFM
No. Motors/HP
Motor RPM
Direct Drive Indoor Fan — Type
No. Used
Diameter x Width (in.)
Drive Type/No. Speeds
No. Motors
Motor HP (Standard/Oversized)
Standard Motor RPM (Low/High Speed)
Oversized Motor RPM (Low/High Speed)
Motor Frame Size (Standard/Oversized)
Belt Drive Indoor Fan — Type
No. Used
Diameter x Width (in.)
Drive Type/No. Speeds
No. Motors
Motor HP
Standard Motor RPM
Motor Frame Size
7
Filters — Type Furnished
(No.) Size Recommended (in.)
Optional Hot Gas Reheat Coil - Type
Tube Size (in.) OD
Face Area (sq. ft)
Rows/FPI
Refrigerant Charge (Lbs of R-22)
Standard
Optional Hot Gas Reheat Coil
NOTES:
1. Cooling Performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is
net and includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Units are certified in accordance with the Unitary Air-Conditioner
Equipment certification program, which is based on ARI Standard 210/240.
2. EER and SEER are rated at ARI conditions and in accordance with DOE test procedures.
3. Outdoor Sound Rating shown is tested in accordance with ARI Standard 270. For more information refer to Table PD-51
4. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions.
5. Refrigerant Charge shown is for 3 phase. 1 phase Refrigerant Charge is 8.1.
6. Belt Drive Motor is not available for THC036A1, THC048A1.
7. Optional 2" Pleated Filters also available.
8. Refrigerant Charge shown is for 3 phase. 1 phase Refrigerant Charge is 4.5.
9. TXV is supplied from the factory as standard with the Dehumidification (Hot Gas Reheat) option.
10. With Dehumidification (Hot Gas Reheat) option: Direct/2.
11. 2" pleated filters is a factory installed option. 2" pleated filters is standard with the Dehumidification (Hot Gas Reheat) option.
RT -PRC005-EN
General
Data
3 Ton
Convertible Units
THC036A1,A3,A4,AW
38,000
12.5/—
1,200/1,200
36,600
3.33
1/Climatuff Scroll
83
Lanced
0.3125
7 .19
2/17
Lanced
0.3125
6.68
3/16
Short Orifice
1/¾ NPT
Propeller
1/22
Direct/1
2550
1/.20
1115
FC Centrifugal
1
10 x 10
Direct/2
1
.33/.50
950/1060
1100/1145
48/48
FC Centrifugal
1
11 x 11
Belt/Variable Speed
6
1
1.00
1750
56
Throwaway
(2) 20 x 25 x 1
4
5.3
8
(3 - 5 Ton)
High Efficiency
4 Ton
Convertible Units
THC048A1,A3,A4,AW
THC060A1
49,800
12.0/—
1,600/1,600
2,000/2,000
47 ,500
4.48
1/Climatuff Scroll
1/Climatuff Scroll
85
Lanced
Lanced
0.3125
9.59
3/17
Lanced
Lanced
0.3125
6.68
4/16
Short Orifice
Short Orifice
1/¾ NPT
1/¾ NPT
Propeller
Propeller
1/22
Direct/1
Direct/1
3050
1/.33
1115
FC Centrifugal
FC Centrifugal
1
11 x 11
Direct/2
Direct/2
1
.60/.80
.90/1.00
930/1000
985/1100
1000/1100
1080/1135
48/48
FC Centrifugal
1
11 x 11
Belt/Variable Speed
6
1
1.00
1750
56
Throwaway
Throwaway
(2) 20 x 25 x 1
(2) 20 x 30 x 1
7 .7
5
5 Ton
Convertible Units
THC060A3,A4,AW
62,100
62,400
11.8/—
12.0/ —
2,000/2,000
59,000
59,500
5.73
5.56
1/Climatuff Scroll
84
84
Lanced
0.3125
0.3125
10.96
10.96
3/17
3/17
Lanced
0.3125
0.3125
7 .71
7 .71
4/16
4/16
Short Orifice
1/¾ NPT
Propeller
1/22
1/22
10
Direct/1
3170
3370
1/.33
1/.33
1115
1115
FC Centrifugal
1
1
11 x 11
11 x 11
Direct/2
1
1
.90/1.00
985/1100
1080/1135
48/48
48/48
FC Centrifugal
1
11 x 11
Belt/Variable Speed
1
1.00
1750
56
Throwaway
(2) 20 x 30 x 1
Lanced
0.375
2.22
2/18
7 .9
8.4
10.7
9
11
13