Trane Precedent RT-PRC005 User Manual page 43

Packaged cooling with electric heat rooftop units 3 - 10 tons - 60 hz
Table of Contents

Advertisement

Table PD-52— Belt Drive Evaporator Fan Performance — 10-Ton — THC120A3,A4,AW — Downflow Airflow
.10
.20
CFM
RPM
BHP
RPM
BHP
3200
3600
4000
734
1.16
4400
764
1.36
795
1.49
4800
828
1.74
857
1.88
For Standard Evaporator Fan Speed (RPM), reference Table PD-50.
NOTES:
NOTES:
NOTES:
NOTES:
NOTES:
Data includes pressure drop due to standard filters and wet coils.
No accessories or options are included in pressure drop data.
Refer to Table PD-54 to determine additional static pressure drop due to other options/accessories
3-HP Fan Motor Heat (MBH) = 2.900 x Fan BHP+.475.
5-HP Fan Motor Heat (MBH) = 2.950 x Fan BHP+.470.
1. Field Supplied Motor Sheave 1VM50 x 7/8 inch, Fan Sheave AK89,
and Belt AX40 required.
Table PD-52 — Continued
1.10
1.20
CFM
RPM
BHP
RPM
BHP
3200
931
1.89
959
2.06
3600
969
2.21
997
2.37
4000
1007
2.57
1034
2.74
4400
1050
2.97
1075
3.17
4800
1095
3.42
1119
3.62
Table PD-53— Belt Drive Evaporator Fan Performance—10-Ton— THC120A3,A4,AW— Downflow Airflow— Dehumidification (Hot Gas Reheat)
.10
.20
CFM
RPM
BHP
RPM
BHP
2000
2400
2800
564
0.50
3200
576
0.57
618
0.67
***MINIMUM AIR VOLUME REQUIRED FOR USE WITH OPTIONAL ELECTRIC HEAT IS 3200 CFM.
***MINIMUM AIR VOLUME REQUIRED FOR USE WITH OPTIONAL ELECTRIC HEAT IS 3200 CFM.
***MINIMUM AIR VOLUME REQUIRED FOR USE WITH OPTIONAL ELECTRIC HEAT IS 3200 CFM.
***MINIMUM AIR VOLUME REQUIRED FOR USE WITH OPTIONAL ELECTRIC HEAT IS 3200 CFM.
***MINIMUM AIR VOLUME REQUIRED FOR USE WITH OPTIONAL ELECTRIC HEAT IS 3200 CFM.
NOTES:
NOTES:
NOTES:
NOTES:
NOTES:
Data includes pressure drop due to standard filters and wet coils.
Data does not include pressure drop due to reheat coil.
3-HP Fan Motor Heat (MBH) = 2.900 x Fan BHP+.475.
1. BAYLSDR010A Required.
2. BAYLSDR010A Required.
Table PD-53 — Continued
1.10
1.20
CFM
RPM
BHP
RPM
BHP
2000
828
1.22
859
1.35
2400
858
1.43
888
1.56
2800
894
1.65
921
1.79
3200
931
1.89
959
2.06
RT -PRC005-EN
Performance
Data
External Static Pressure (Inches of Water)
.30
.40
RPM
BHP
RPM
BHP
RPM
3-HP Standard Motor & Field Supplied Low Static Drive (1)
734
714
1.02
749
1.14
782
768
1.30
803
1.44
834
825
1.63
857
1.79
888
884
2.02
913
2.18
942
External Static Pressure (Inches of Water)
1.30
1.40
RPM
BHP
RPM
BHP
RPM
986
2.22
1012
2.39
1037
1024
2.54
1050
2.72
1074
1062
2.93
1087
3.11
1112
1101
3.36
1126
3.55
1150
1143
3.83
1166
4.05
1189
External Static Pressure (Inches of Water)
.30
.40
RPM
BHP
RPM
BHP
RPM
3-HP Standard Motor & Low
Static Drive Accessory Kit (1)
568
0.43
613
606
0.56
650
607
0.60
649
0.71
689
659
0.79
697
0.90
734
External Static Pressure (Inches of Water)
1.30
1.40
RPM
BHP
RPM
BHP
RPM
888
1.48
917
1.61
945
916
1.70
945
1.85
972
949
1.95
975
2.11
1001
986
2.22
1012
2.39
1037
(10 Ton)
High Efficiency
.50
.60
.70
BHP
RPM
BHP
RPM
1.03
770
1.17
804
1.27
815
1.41
847
1.58
863
1.72
894
1.95
916
2.10
943
2.36
970
2.53
996
3-HP Standard Motor & Drive
Trane's factory supplied motors, in commercial equipment, are definite purpose
motors, specifically designed and tested to operate reliably and continuously at
all cataloged conditions. Using the full horsepower range of our fan motors as
shown in our tabular data will not result in nuisance tripping or premature motor
failure. Our product's warranty will not be affected.
1.50
1.60
1.70
BHP
RPM
BHP
RPM
2.56
1061
2.74
1084
2.89
1098
3.08
1122
3.29
1136
3.47
1159
3.75
1173
3.94
1 198
4.26
1212
4.47
1235
5-HP Oversized Motor & Drive
.50
.60
.70
BHP
RPM
BHP
RPM
0.53
653
0.64
691
0.67
691
0.78
728
0.83
728
0.95
766
1.03
770
1.17
804
Trane's factory supplied motors, in commercial
equipment, are definite purpose motors, specifically
designed and tested to operate reliably and
continuously at all cataloged conditions. Using the full
horsepower range of our fan motors as shown in our
tabular data will not result in nuisance tripping or
premature motor failure. Our product's warranty will
not be affected.
1.50
1.60
1.70
BHP
RPM
BHP
RPM
3 HP Standard Motor & Drive
1.75
971
1.88
998
1.99
998
2.14
1023
2.27
1027
2.43
1051
2.56
1061
2.74
1084
.80
.90
BHP
RPM
BHP
RPM BHP
1.31
839
1.45
871
1.60
1.57
879
1.73
909
1.89
1.87
923
2.04
952
2.21
2.25
970
2.41
997
2.59
2.70
1021
2.86
1045 3.03
1.80
1.90
BHP
RPM
BHP
RPM
BHP
2.91
1108
3.09
1131
3.28
3.27
1145
3.46
1166
3.65
3.66
1182
3.86
1204
4.07
4.15
1219
4.34
1241
4.54
4.68
1258
4.90
1280
5.12
.80
.90
BHP
RPM
BHP
RPM
BHP
3-HP Standard Motor & Low
Static Drive Accessory Kit (2)
0.75
727
0.86
763
0.98
0.90
763
1.02
796
1.16
1.08
801
1.21
833
1.35
1.31
839
1.45
871
1.60
1.80
1.90
BHP
RPM
BHP
RPM
BHP
2.03
1023
2.19
1048
2.35
2.29
1050
2.45
1073
2.60
2.59
1076
2.75
1100
2.92
2.91
1108
3.09
1131
3.28
1.00
RPM BHP
901
1.74
939
2.04
979
2.39
1024 2.78
1070 3.22
2.00
RPM
BHP
1153
3.46
1188
3.85
1226
4.28
1264
4.77
1300
5.32
1.00
RPM
BHP
797
1.10
826
1.29
864
1.50
901
1.74
2.00
RPM
BHP
1072
2.50
1097
2.76
1123
3.09
43

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents