Daylight Savings Time Configuration - Alcatel-Lucent OmniSwitch AOS Release 6 Manual

Omniswitch series
Table of Contents

Advertisement

Managing System Files

Daylight Savings Time Configuration

The switch can be set to change the system clock automatically to adjust for Daylight Savings Time
(DST). There are two situations that apply depending on the time zone selected for your switch.
If the time zone set for your switch shows DST parameters in the table on
enable DST on your switch by using the following command:
-> system daylight savings time enable
If the time zone set for your switch does not show DST parameters in the table on
specify the start, end, and change parameters for DST by using the
command. The following information is needed to specify DST:
The day of the week and month of the year when DST will begin.
The position of that day in the month (e.g., first, second, third, fourth, or last Sunday of the month).
The hour and minute of the day at which DST will begin.
The day of the week and month of the year when DST will end.
The position of that day in the month (e.g., first, second, third, fourth, or last Sunday of the month).
The hour and minute of the day at which DST will end.
The number of hours the switch clock will be offset for DST (one hour in most cases).
To set the switch DST parameters so that the clock will move back one hour on the fourth Sunday of
September at 11:00 p.m. and move forward on the fourth Sunday of March at 11:00 a.m., the following
command should be used:
-> system daylight savings time start fourth sun in Sept at 23:00 end fourth sun
in march at 11:00 by 1
For more details on syntax for this command, please refer to the OmniSwitch CLI Reference Guide. You
can also use the question mark (?) character in the command syntax to invoke the CLI's help feature as
described in the "Using the CLI" chapter of this manual.
Note. By default, Daylight Savings Time is disabled.
OmniSwitch AOS Release 6 Switch Management Guide
page
system daylight savings time
July 2010
Setting the System Clock
1-40, you need to only
page
1-40, you must
page 1-39