SERVICE MANUAL
23JUL01
Installation for the FOCUS SHAFT ASSEMBLY - 1500 and
SM5766-1
Page
2000 PROJECTORS Only
38 of 96
Important
Do the adjustments for the PHOTOCELL NULL and AUTO-FOCUS CLAMP after installation.
See the Adjustments section.
Removal for the FOCUS SHAFT ASSEMBLY - 500 and
1000 PROJECTORS Only
Warning
Dangerous Voltage
1
Disconnect the main power.
2
Do the removal for the LOWER HOUSING ASSEMBLY.
3
Disconnect the 3 CONNECTORS on the MAIN BOARD. It is not necessary to disconnect
the CONNECTOR next to the LOWER LIGHT BAFFLE ASSEMBLY.
4
Lift the MAIN BOARD up.
5
Remove the FOCUS KNOB.
6
Remove the 3 SCREWS from the LENS MOUNT ASSEMBLY.
7
Lift and remove the LENS MOUNT ASSEMBLY.
8
Remove the FOCUS SHAFT SPRING from the LENS MOUNT BRACKET.
9
Remove the E-RING and SPACER from the FOCUS SHAFT ASSEMBLY.
10
Remove the SCREW from the LENS SUPPORT BRACKET.
11
Lift and remove the LENS SUPPORT BRACKET.
12
Remove the E-RING and SPACER from the FOCUS SHAFT ASSEMBLY.
13
Remove the SCREW from the FOCUS MOTOR BRACKET ASSEMBLY.
14
Remove the FOCUS MOTOR BRACKET ASSEMBLY.
Removals and Installations