SERVICE MANUAL
23JUL01

DARK SHUTTER

SM5766-1
Page
1
Do the removal for the LOWER HOUSING.
57 of 96
2
Insert a thin SLIDE into the GATE MECHANISM; the DARK SHUTTER should open.
3
Check the PRESSURE PAD is correctly aligned with the DARK SHUTTER.
4
Bend the PRESSURE PAD to adjust the alignment.
DARK
SHUTTER
PRESSURE
PAD
A091_0013GCA
A091_0013GA