Installation For The Motor; Removal For The Worm Pulley And Mechanism Belt - Kodak Ektalite 500 Service Manual

Hide thumbs Also See for Ektalite 500:
Table of Contents

Advertisement

SERVICE MANUAL
23JUL01

Installation for the MOTOR

SM5766-1
Page
13 of 96
Important
When installing the FAN and MECHANISM BELTS, install the MECHANISM BELT on the
small MOTOR PULLEY, and the FAN BELT on the large MOTOR PULLEY.
1
Do the removal for the MOTOR in reverse order.

Removal for the WORM PULLEY and MECHANISM BELT

Warning
Dangerous Voltage
1
Disconnect the main power.
2
Do the removal for the LOWER HOUSING ASSEMBLY.
3
Do the removal for the MOTOR except do not disconnect the wires from the MOTOR.
4
Remove the Torx SCREW from the WORM PULLEY ASSEMBLY.
FAN BELT
MECHANISM BELT
Removals and Installations
A091_4015BCA
A091_4015BA