SERVICE MANUAL
23JUL01
SM5766-1
Page
Safety
67 of 96
Dielectric strength
Automatic Timer
Elevation
3 GROUNDED POWER CORDS,
detachable
Heat sensitive interrupt fuses
117 C ° LAMP THERMAL FUSE
169 C ° MOTOR THERMAL
FUSE
150 C ° TRANSFORMER
SAFETY INTERLOCK SWITCH,
deenergizes projector when the
LAMP MODULE is removed.
Apply 1200 V, 50 Hz for 1 second;
maximum leakage current is 2.5 mA.
Models 1500 and 2000 Only:
Operates between the following
times:
Fast = 3 ± 1 second
Slow = 22 ± 6 seconds
16
maximum front elevation
assembly.
Specifications